Management of in-tube projectiles using acoustic channel

Bibliographic Details
Parent link:IOP Conference Series: Materials Science and Engineering
Vol. 327 : Mechanical Engineering, Automation and Control Systems (MEACS 2017).— 2018.— [042055, 8 p.]
Corporate Author: Национальный исследовательский Томский политехнический университет Инженерная школа неразрушающего контроля и безопасности Отделение электронной инженерии
Other Authors: Kostina M. A. Maria Alekseevna, Bortalevich S. I., Loginov E. L., Shinyakov Y. A., Sukhorukov M. P.
Summary:Title screen
The article describes the method of measuring the distance from the operator's console installed outside the pipe to the in-tube projectile. A method for measuring distance in the absence of an echo signal is proposed. To do this, two identical ultrasonic locators operating at different frequencies were installed inside and outside the pipeline. The change in the duration of an acoustic pulse propagating in a circular waveguide with rigid walls is shown, which leads to a decrease in the data transfer rate.
Published: 2018
Series:Processing Equipment, Mechanical Engineering Processes and Metals Treatment
Subjects:
Online Access:https://doi.org/10.1088/1757-899X/327/4/042055
http://earchive.tpu.ru/handle/11683/52285
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=659038

MARC

LEADER 00000nla2a2200000 4500
001 659038
005 20231101135044.0
035 |a (RuTPU)RU\TPU\network\27353 
035 |a RU\TPU\network\27351 
090 |a 659038 
100 |a 20181222d2018 k y0engy50 ba 
101 0 |a eng 
102 |a GB 
105 |a y z 100zy 
135 |a vrgn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Management of in-tube projectiles using acoustic channel  |f M. A. Kostina [et al.] 
203 |a Text  |c electronic 
225 1 |a Processing Equipment, Mechanical Engineering Processes and Metals Treatment 
300 |a Title screen 
320 |a [References: 19 tit.] 
330 |a The article describes the method of measuring the distance from the operator's console installed outside the pipe to the in-tube projectile. A method for measuring distance in the absence of an echo signal is proposed. To do this, two identical ultrasonic locators operating at different frequencies were installed inside and outside the pipeline. The change in the duration of an acoustic pulse propagating in a circular waveguide with rigid walls is shown, which leads to a decrease in the data transfer rate. 
461 1 |0 (RuTPU)RU\TPU\network\2008  |t IOP Conference Series: Materials Science and Engineering 
463 1 |0 (RuTPU)RU\TPU\network\25712  |t Vol. 327 : Mechanical Engineering, Automation and Control Systems (MEACS 2017)  |o International Conference, 4–6 December 2017, Tomsk, Russian Federation  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU)  |v [042055, 8 p.]  |d 2018 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a снаряды 
610 1 |a акустические сигналы 
610 1 |a эхо-сигналы 
610 1 |a трубопроводы 
610 1 |a волноводы 
701 1 |a Kostina  |b M. A.  |c specialist in the field of electronics  |c Assistant of the Department of Tomsk Polytechnic University  |f 1991-  |g Maria Alekseevna  |2 stltpush  |3 (RuTPU)RU\TPU\pers\42383 
701 1 |a Bortalevich  |b S. I. 
701 1 |a Loginov  |b E. L. 
701 1 |a Shinyakov  |b Y. A. 
701 1 |a Sukhorukov  |b M. P. 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа неразрушающего контроля и безопасности  |b Отделение электронной инженерии  |h 7977  |2 stltpush  |3 (RuTPU)RU\TPU\col\23507 
801 1 |a RU  |b 63413507  |c 20150101  |g RCR 
801 2 |a RU  |b 63413507  |c 20190117  |g RCR 
856 4 |u https://doi.org/10.1088/1757-899X/327/4/042055 
856 4 |u http://earchive.tpu.ru/handle/11683/52285 
942 |c CF