Floating harmonic probe measurements in the low-temperature plasma jet deposition system

書目詳細資料
Parent link:Journal of Physics D: Applied Physics.— , 1950-
Vol. 51.— 2017.— [9 p., 025205]
其他作者: Zanaska M., Hubicka Zdenek, Cada M. Martin, Kudrna P. Pavel, Tichy M. Milan
總結:Title screen
The floating harmonic probe is a relatively new plasma diagnostic method, which was proposed for applications at conditions when insulating films are deposited on the probe and, consequently, the classical Langmuir probe method fails. In the floating harmonic probe method a purely sinusoidal AC voltage is applied to the probe constructed in a standard manner via a capacitor. From the spectral components of the measured AC probe current waveforms, the electron temperature and the positive ion density can be obtained. In this contribution we present the comparison of the electron temperature and density acquired by the floating harmonic probe method with those obtained by the classical Langmuir probe. The experiments are performed in the flowing DC discharge in argon. In addition, the results from the floating harmonic probe method obtained during deposition of an insulating iron oxide thin film are shown. All the data is complemented by the qualitative discussion.
Режим доступа: по договору с организацией-держателем ресурса
語言:英语
出版: 2017
主題:
在線閱讀:http://dx.doi.org/10.1088/1361-6463/aa9d3b
格式: 電子 Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=657800

MARC

LEADER 00000naa0a2200000 4500
001 657800
005 20250123143552.0
035 |a (RuTPU)RU\TPU\network\24575 
035 |a RU\TPU\network\20260 
090 |a 657800 
100 |a 20180322d2017 k||y0engy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Floating harmonic probe measurements in the low-temperature plasma jet deposition system  |f M. Zanaska, Hubicka Zdenek, M. Cada [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 36 tit.] 
330 |a The floating harmonic probe is a relatively new plasma diagnostic method, which was proposed for applications at conditions when insulating films are deposited on the probe and, consequently, the classical Langmuir probe method fails. In the floating harmonic probe method a purely sinusoidal AC voltage is applied to the probe constructed in a standard manner via a capacitor. From the spectral components of the measured AC probe current waveforms, the electron temperature and the positive ion density can be obtained. In this contribution we present the comparison of the electron temperature and density acquired by the floating harmonic probe method with those obtained by the classical Langmuir probe. The experiments are performed in the flowing DC discharge in argon. In addition, the results from the floating harmonic probe method obtained during deposition of an insulating iron oxide thin film are shown. All the data is complemented by the qualitative discussion. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Journal of Physics D: Applied Physics  |d 1950- 
463 |t Vol. 51  |v [9 p., 025205]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a plasma 
610 1 |a cathode 
610 1 |a плазма 
610 1 |a зонды 
610 1 |a полые катоды 
610 1 |a низкотемпературные системы 
610 1 |a струйное напыление 
701 1 |a Zanaska  |b M. 
701 0 |a Hubicka Zdenek 
701 1 |a Cada  |b M.  |g Martin 
701 1 |a Kudrna  |b P.  |g Pavel 
701 1 |a Tichy  |b M.  |c chemist  |c Professor of Tomsk Polytechnic University, Doctor of physical and mathematical sciences  |f 1947-  |g Milan  |3 (RuTPU)RU\TPU\pers\35771 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |b Инженерная школа ядерных технологий  |b Отделение ядерно-топливного цикла  |3 (RuTPU)RU\TPU\col\23554 
801 2 |a RU  |b 63413507  |c 20210616  |g RCR 
856 4 |u http://dx.doi.org/10.1088/1361-6463/aa9d3b 
942 |c CF