Detection of insulation defects in the wire through measuring changes in its capacitance; IOP Conference Series: Materials Science and Engineering; Vol. 289 : Modern Technologies for Non-Destructive Testing

Podrobná bibliografie
Parent link:IOP Conference Series: Materials Science and Engineering
Vol. 289 : Modern Technologies for Non-Destructive Testing.— 2018.— [012017, 6 p.]
Hlavní autor: Vavilova G. V. Galina Vasilievna
Korporativní autor: Национальный исследовательский Томский политехнический университет Инженерная школа неразрушающего контроля и безопасности Отделение контроля и диагностики
Další autoři: Ryumkin A. V.
Shrnutí:Title screen
The paper describes the technique to detect local wire insulation defects through measuring the wire capacitance. The operating principle of the CAP-10 device is explained. The principal possibility of this device to detect local defects in wire insulation is shown. The experiments showed that the device can be used to detect defects of different types.
Jazyk:angličtina
Vydáno: 2018
Témata:
On-line přístup:http://dx.doi.org/10.1088/1757-899X/289/1/012017