الملخص:Title screen
This study aims to define some recommendations for choice of grounding system type for power supply facility. Operating modes of 0.4 kV networks approved by International Electrotechnical Commission (IEC) were considered and their advantages and disadvantages were identified. The comparison criteria were based on the conditions of human safety from electric shock in the breakdown of insulation on the body of electrical equipment, possibilities of expanding the network and uninterruptible power supply. The real application of the neutral modes and the possibility of installing protective devices were also taken into account. All the recommendations made is planned to apply for the modernization of the urban networks and the calculation of the earthing arrangement by using special software.
اللغة:الإنجليزية
منشور في: 2017
الموضوعات:
الوصول للمادة أونلاين:https://doi.org/10.1051/matecconf/201714101052
http://earchive.tpu.ru/handle/11683/46041
التنسيق: الكتروني فصل الكتاب
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=657329

MARC

LEADER 00000nla2a2200000 4500
001 657329
005 20260720171134.0
035 |a (RuTPU)RU\TPU\network\23831 
035 |a RU\TPU\network\23830 
090 |a 657329 
100 |a 20180123a2017 k y0engy50 ba 
101 0 |a eng 
105 |a y z 100zy 
135 |a drgn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Grounding systems for power supply facilities  |f V. Konusarov, E. S. Tarasova 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 3 tit.] 
330 |a This study aims to define some recommendations for choice of grounding system type for power supply facility. Operating modes of 0.4 kV networks approved by International Electrotechnical Commission (IEC) were considered and their advantages and disadvantages were identified. The comparison criteria were based on the conditions of human safety from electric shock in the breakdown of insulation on the body of electrical equipment, possibilities of expanding the network and uninterruptible power supply. The real application of the neutral modes and the possibility of installing protective devices were also taken into account. All the recommendations made is planned to apply for the modernization of the urban networks and the calculation of the earthing arrangement by using special software. 
461 0 |0 (RuTPU)RU\TPU\network\4526  |t MATEC Web of Conferences 
463 0 |0 (RuTPU)RU\TPU\network\23742  |t Vol. 141 : Smart Grids 2017  |o The Fifth International Youth Forum, October 9-13, 2017, Tomsk, Russia  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU) ; eds. A. A. Kozyreva, A. O. Zhdanova, G. V. Kuznetsov  |v [01052, 5 p.]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a заземление 
610 1 |a электроснабжение 
610 1 |a объекты 
610 1 |a заземляющие системы 
610 1 |a безопасность 
610 1 |a электрический ток 
610 1 |a пробой 
610 1 |a изоляция 
610 1 |a защитные устройства 
610 1 |a городские сети 
610 1 |a программное обеспечение 
700 1 |a Konusarov  |b V.  |g Vladimir 
701 1 |a Tarasova  |b E. S.  |c linguist  |c associate Professor of Tomsk Polytechnic University, candidate of pedagogical Sciences  |f 1984-  |g Ekaterina Sergeevna  |3 (RuTPU)RU\TPU\pers\31732 
712 0 2 |a Томский политехнический университет  |c 1991-  |9 26305 
801 2 |a RU  |b 63413507  |c 20180426  |g RCR 
856 4 |u https://doi.org/10.1051/matecconf/201714101052 
856 4 |u http://earchive.tpu.ru/handle/11683/46041 
942 |c CF