New method of measuring µ-focus spots of X-ray tubes; Journal of Physics: Conference Series; Vol. 881 : Innovations in Non-Destructive Testing (SibTest 2017)
| Parent link: | Journal of Physics: Conference Series Vol. 881 : Innovations in Non-Destructive Testing (SibTest 2017).— 2017.— [012031, 6 p.] |
|---|---|
| Corporate Author: | Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра физических методов и приборов контроля качества (ФМПК) |
| Other Authors: | Gnedin M., Usachev E., Valikov V., Gheveler V., Stein A. M. Aleksandr Mikhailovich |
| Summary: | Title screen The practice of non-destructive testing shows that despite the whole range of working standards that define the methods of measurement of µ-focus spot sizes, the consistency and spread of the obtained results are considered unsatisfactory. In the meantime, knowing the accurate size of µ-focus spot is the determinant factor in optimization of control parameters, which is often carried out with geometric magnification. A new design of test object is proposed, a new method of differentiated line profiles of test object digital image is developed and tested, the computing chain and allowances are described. The obtained results have formed the basis for elaboration of a Standard to measure µ-focus spot size of an X-ray tube. Режим доступа: по договору с организацией-держателем ресурса |
| Language: | English |
| Published: |
2017
|
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1088/1742-6596/881/1/012031 http://earchive.tpu.ru/handle/11683/43864 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=656301 |
Similar Items
Новый метод измерения размера микрофокусных пятен рентгеновских трубок; Инновации в неразрушающем контроле (SibTest 2017)
Published: (2017)
Published: (2017)
Focal Spot Size Estimation for a 4 MeV Small-size Betatron Using Digital X-ray Detector; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Sukharnikov K. V. Konstantin Vladimirovich
Published: (2016)
by: Sukharnikov K. V. Konstantin Vladimirovich
Published: (2016)
Analytical Approximation of Spectrum for Pulse X-ray Tubes; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
Published: (2016)
Published: (2016)
Simulation of the Focal Spot of the Accelerator Bremsstrahlung Radiation; IOP Conference Series: Materials Science and Engineering; Vol. 132 : Modern Technologies for Non-Destructive Testing
by: Sorokin V. B. Vladimir Borisovich
Published: (2016)
by: Sorokin V. B. Vladimir Borisovich
Published: (2016)
Method for Automated Bone Shape Correction within Bone Distraction Procedure; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Blynsky F. Yu. Fedor Yuryevich
Published: (2016)
by: Blynsky F. Yu. Fedor Yuryevich
Published: (2016)
The Monte Carlo study of techniques for determining bremsstrahlung focal spots; Russian Journal of Nondestructive Testing; Vol. 53, iss. 1
by: Bespalov V. I. Valery Ivanovich
Published: (2017)
by: Bespalov V. I. Valery Ivanovich
Published: (2017)
Measurement Technique of Dose Rate Distribution of Ionization Sources with Unstable in Time Beam Parameters; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
Determination of the modulation transfer function in betatron tomography; Journal of Physics: Conference Series; Vol. 881 : Innovations in Non-Destructive Testing (SibTest 2017)
Published: (2017)
Published: (2017)
The Dosimetric Parameters Investigation of the Pulsed X-ray and Gamma Radiation Sources; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
A Study of a Method for Determining the Size of a Bremsstrahlung Focal Spot Using a Slit Collimator; Instruments and Experimental Techniques; Vol. 63, iss. 1
by: Sorokin V. B. Vladimir Borisovich
Published: (2020)
by: Sorokin V. B. Vladimir Borisovich
Published: (2020)
Use of a Slit Collimator for Determining the Focal-Spot Size of Betatron Bremsstrahlung; Instruments and Experimental Techniques; Vol. 61, iss. 2
by: Sorokin V. B. Vladimir Borisovich
Published: (2018)
by: Sorokin V. B. Vladimir Borisovich
Published: (2018)
Linear microfocus bremsstrahlung generated in light and heavy narrow targets in B-18 betatron; Journal of Physics: Conference Series; Vol. 881 : Innovations in Non-Destructive Testing (SibTest 2017)
Published: (2017)
Published: (2017)
Research of X-ray tube energy characteristics; Перспективы развития фундаментальных наук; Т. 1 : Физика
by: Baulin A. A.
Published: (2017)
by: Baulin A. A.
Published: (2017)
State of the Art and Development Trends of the Digital Radiography Systems for Cargo Inspection; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
Published: (2016)
Published: (2016)
Modernization of the X-Ray Tomographic Scanner Based on Gas-Discharge Linear Detector; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
Особенности скользящего взаимодействия микрофокусного тормозного излучения с краевой поверхностью; Ресурсоэффективные системы в управлении и контроле: взгляд в будущее
by: Смолянский В. А. Владимир Александрович
Published: (2022)
by: Смолянский В. А. Владимир Александрович
Published: (2022)
The X-ray Beam Passage through the Collimator Made of Different Materials: Numerical Simulation; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
by: Stuchebrov S. G. Sergey Gennadevich
Published: (2016)
Исследование коллекторов углеводородов методами компьютерной томографии; Инновации в неразрушающем контроле (SibTest 2017)
by: Батранин А. В. Андрей Викторович
Published: (2017)
by: Батранин А. В. Андрей Викторович
Published: (2017)
Features of X-ray Absorption Densitometry of Large-size Objects with Variable Thickness; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
Published: (2016)
Published: (2016)
Комплекс на основе CuBr-лазера для визуально-оптического исследования сварочных процессов; Инновации в неразрушающем контроле (SibTest 2017)
by: Тригуб М. В. Максим Викторович
Published: (2017)
by: Тригуб М. В. Максим Викторович
Published: (2017)
Object’s Border and Position Allocating in an X-Ray Image; Applied Mechanics and Materials; Vol. 756 : Mechanical Engineering, Automation and Control Systems (MEACS2014)
by: Tsapko I. V. Irina Valerievna
Published: (2015)
by: Tsapko I. V. Irina Valerievna
Published: (2015)
Generation and Analysis of Wire Rope Digital Radiographic Images; IOP Conference Series: Materials Science and Engineering; Vol. 132 : Modern Technologies for Non-Destructive Testing
Published: (2016)
Published: (2016)
Исследование метода определения размера фокусного пятна тормозного излучения с использованием щелевого коллиматора; Приборы и техника эксперимента; № 1
by: Сорокин В. Б. Владимир Борисович
Published: (2020)
by: Сорокин В. Б. Владимир Борисович
Published: (2020)
Источник тормозного излучения с фокусным пятном малых размеров
by: Сорокин В. Б. Владимир Борисович
Published: ()
by: Сорокин В. Б. Владимир Борисович
Published: ()
Результаты измерения фокусного пятна и тепловых испытаний бетатрона с последовательно-встречным включением обмоток возбуждения и компенсационной; Современные техника и технологии - СТТ' 2002; Т. 1
by: Чертов А. С.
Published: (2002)
by: Чертов А. С.
Published: (2002)
Исследование методом Монте-Карло методик определения фокусного пятна тормозного излучения; Дефектоскопия; № 1
by: Беспалов В. И. Валерий Иванович
Published: (2017)
by: Беспалов В. И. Валерий Иванович
Published: (2017)
Томографическая визуализация рентгеновских изображений с субмиллиметровым пространственным разрешением на основе импульсных источников: диссертация на соискание ученой степени кандидата физико-математических наук; спец. 01.04.20
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
Телевизионные методы обработки рентгеновских и гамма-изображений
Published: (Москва, Энергоиздат, 1982)
Published: (Москва, Энергоиздат, 1982)
Воздушный газоразрядный преобразователь для визуализации рентгеновских изображений пикосекундной длительности: диссертация на соискание ученой степени кандидата технических наук; спец. 05.11.13
by: Ларионов С. С. Сергей Семенович
Published: (Томск, 1988)
by: Ларионов С. С. Сергей Семенович
Published: (Томск, 1988)
Томографическая визуализация рентгеновских изображений с субмиллиметровым пространственным разрешением на основе импульсных источников: автореферат диссертации на соискание ученой степени кандидата физико-математических наук; спец. 01.04.20
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
Управляемые трубки Рентгена. (Трубки Кулиджа и Лилиенфельда). Ч. 1
by: Успенский Н. Николай
Published: (Москва, Типография Т. Ф. Дортман, 1916)
by: Успенский Н. Николай
Published: (Москва, Типография Т. Ф. Дортман, 1916)
A theoretical approach for the reduction of X-ray radiation dose within the optimization of the tomographic scanning process; Journal of Physics: Conference Series; Vol. 1327 : Innovations in Non-Destructive Testing (SibTest 2019)
by: Ozdiev A. H. Ali Hosenovich
Published: (2019)
by: Ozdiev A. H. Ali Hosenovich
Published: (2019)
Определение размеров фокусного пятна тормозного излучения бетатрона с использованием щелевого коллиматора; Приборы и техника эксперимента; № 2
by: Сорокин В. Б. Владимир Борисович
Published: (2018)
by: Сорокин В. Б. Владимир Борисович
Published: (2018)
Оценка размеров фокусного пятна малогабаритного бетатрона с помощью цифрового детектора; Информационные технологии неразрушающего контроля
by: Сухарников К. В. Константин Владимирович
Published: (2015)
by: Сухарников К. В. Константин Владимирович
Published: (2015)
Ptychographic X-Ray Imaging of Colloidal Crystals; Small; Vol. 14, iss. 3
Published: (2018)
Published: (2018)
Mass Determination Algorithms Using High Energy Digital Radiography; Advanced Materials Research; Vol. 1085 : Prospects of Fundamental Sciences Development (PFSD-2014)
Published: (2015)
Published: (2015)
Методы рентгеновского фазового контраста; Функциональные материалы: разработка, исследование, применение
by: Купин А.
Published: (2018)
by: Купин А.
Published: (2018)
Томографическая визуализация рентгеновских изображений с субмиллиметровым пространственным разрешением на основе импульсных источников: автореферат диссертации на соискание ученой степени кандидата физико-математических наук; спец. 01.04.20
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
by: Стучебров С. Г. Сергей Геннадьевич
Published: (Томск, 2014)
Определение функции передачи модуляции бетатронного томографа; Инновации в неразрушающем контроле (SibTest 2017)
Published: (2017)
Published: (2017)
Вакуумные и плазменные приборы и устройства учебное пособие для студентов направления подготовки 11.03.04 - «электроника и наноэлектроника»
by: Аксенов А. И.
Published: (Москва, ТУСУР, 2018)
by: Аксенов А. И.
Published: (Москва, ТУСУР, 2018)
Similar Items
-
Новый метод измерения размера микрофокусных пятен рентгеновских трубок; Инновации в неразрушающем контроле (SibTest 2017)
Published: (2017) -
Focal Spot Size Estimation for a 4 MeV Small-size Betatron Using Digital X-ray Detector; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Sukharnikov K. V. Konstantin Vladimirovich
Published: (2016) -
Analytical Approximation of Spectrum for Pulse X-ray Tubes; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
Published: (2016) -
Simulation of the Focal Spot of the Accelerator Bremsstrahlung Radiation; IOP Conference Series: Materials Science and Engineering; Vol. 132 : Modern Technologies for Non-Destructive Testing
by: Sorokin V. B. Vladimir Borisovich
Published: (2016) -
Method for Automated Bone Shape Correction within Bone Distraction Procedure; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
by: Blynsky F. Yu. Fedor Yuryevich
Published: (2016)