Evaluation of freeze-thaw damage to reinforced concrete based on the parameters of electric response to mechanical impact; Construction and Building Materials; Vol. 155

מידע ביבליוגרפי
Parent link:Construction and Building Materials: International Journal
Vol. 155.— 2017.— [P. 451-462]
מחבר ראשי: Fursa T. V. Tatyana Viktorovna
מחבר תאגידי: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)
מחברים אחרים: Dann D. D. Denis Dmitrievich, Petrov M. V. Maksim Vyacheslavovich
סיכום:Title screen
The article examines damage caused to steel and fiberglass reinforcement concrete by freeze-thaw cycles in saline medium conditions. After 12 freeze-thawing cycles, the concrete-rebar bond strength decreases by 30% for steel and by 40% for fiberglass. A method of evaluating the concrete-rebar bond strength is proposed. The evaluation procedure is based on measuring electric response to mechanical impact. Energy attenuation coefficient and the signals' spectrum centroid could be used as the diagnostic criteria for the evaluation of concrete-rebar bond strength. After 12 FT cycles the electric signal's energy attenuation coefficient increases by about 40–45%, and the maximum signals' spectrum centroid increasing reaches about 8 kHz. The proposed method can be used to monitor the evolution of concrete-rebar bond strength in complex climate testing conditions.
Режим доступа: по договору с организацией-держателем ресурса
שפה:אנגלית
יצא לאור: 2017
נושאים:
גישה מקוונת:https://doi.org/10.1016/j.conbuildmat.2017.08.099
פורמט: אלקטרוני Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=656098

MARC

LEADER 00000naa0a2200000 4500
001 656098
005 20250402100327.0
035 |a (RuTPU)RU\TPU\network\22489 
090 |a 656098 
100 |a 20171024d2017 k||y0rusy50 ba 
101 0 |a eng 
102 |a GB 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Evaluation of freeze-thaw damage to reinforced concrete based on the parameters of electric response to mechanical impact  |f T. V. Fursa, D. D. Dann, M. V. Petrov 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 43 tit.] 
330 |a The article examines damage caused to steel and fiberglass reinforcement concrete by freeze-thaw cycles in saline medium conditions. After 12 freeze-thawing cycles, the concrete-rebar bond strength decreases by 30% for steel and by 40% for fiberglass. A method of evaluating the concrete-rebar bond strength is proposed. The evaluation procedure is based on measuring electric response to mechanical impact. Energy attenuation coefficient and the signals' spectrum centroid could be used as the diagnostic criteria for the evaluation of concrete-rebar bond strength. After 12 FT cycles the electric signal's energy attenuation coefficient increases by about 40–45%, and the maximum signals' spectrum centroid increasing reaches about 8 kHz. The proposed method can be used to monitor the evolution of concrete-rebar bond strength in complex climate testing conditions. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Construction and Building Materials  |o International Journal 
463 |t Vol. 155  |v [P. 451-462]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a замораживание 
610 1 |a оттаивание 
610 1 |a бетоны 
610 1 |a электрический отклик 
610 1 |a прочность 
610 1 |a испытания 
700 1 |a Fursa  |b T. V.  |c specialist in the field of non-destructive testing  |c Leading researcher of Tomsk Polytechnic University, Doctor of technical sciences  |f 1951-  |g Tatyana Viktorovna  |3 (RuTPU)RU\TPU\pers\32190 
701 1 |a Dann  |b D. D.  |c specialist in the field of electrical engineering  |c Engineer-researcher of Tomsk Polytechnic University  |f 1987-  |g Denis Dmitrievich  |3 (RuTPU)RU\TPU\pers\32192 
701 1 |a Petrov  |b M. V.  |c specialist in the field of non-destructive testing  |c Associate Scientist of Tomsk Polytechnic University  |f 1992-  |g Maksim Vyacheslavovich  |3 (RuTPU)RU\TPU\pers\36439 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)  |3 (RuTPU)RU\TPU\col\19033 
801 2 |a RU  |b 63413507  |c 20181213  |g RCR 
856 4 |u https://doi.org/10.1016/j.conbuildmat.2017.08.099 
942 |c CF