Tree-inception in PMMA with a barrier; Journal of Physics D: Applied Physics; Vol. 37, iss. 16
| Parent link: | Journal of Physics D: Applied Physics Vol. 37, iss. 16.— 2004.— [2318-2322] |
|---|---|
| Další autoři: | , , , , |
| Shrnutí: | Title screen The experimental results of a study of the tree-inception phenomenon for three-layer dielectrics in a divergent field are presented in this paper. It is shown that the tree-inception time depends on both the position of the high-permittivity barrier in the insulating gap and the ratio of the permittivities of the barrier material and main dielectric, and that it has a maximum at the optimal barrier position. It is found that the tree-inception length has a minimum value at this barrier position. Good agreement between the coefficient of the local field non-uniformity and the tree-inception time or the initial tree length was found. Режим доступа: по договору с организацией-держателем ресурса |
| Jazyk: | angličtina |
| Vydáno: |
2004
|
| Témata: | |
| On-line přístup: | http://dx.doi.org/10.1088/0022-3727/37/16/015 |
| Médium: | MixedMaterials Elektronický zdroj Kapitola |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=656076 |