Breakup of heterogeneous water drop immersed in high-temperature air; Applied Thermal Engineering; Vol. 127
| Parent link: | Applied Thermal Engineering Vol. 127.— 2017.— [P. 1340-1345] |
|---|---|
| 1. autor: | |
| organizacja autorów: | , |
| Kolejni autorzy: | , |
| Streszczenie: | Title screen The enhancement of the evaporation rate of a heterogeneous water drop is experimentally investigated. A water drop encapsulating a solid graphite inclusion is instantaneously placed in the very hot air. Under action of the high ambient temperature and due to different thermal properties between water and solid inclusion, the initial drop explodes and creates numerous very small droplets. The vaporization rate of the water drop is strongly increased leading to a short time life of the drop. High speed video recording is used to detail the explosive breakup mechanism of a drop immersed in hot air when its temperature varies in the range between 1073 K and 1373 K. The target of the study is to determine the possible conditions for the increase of the water/air surface of the drop after breakup, i.e., the ratio of the final to initial surface, Sout/Sin, and to verify that this enlargement is responsible of the evaporation rate enhancement. For this purpose, we investigate drops of different initial volumes (5-15 µl) with graphite solid inclusions of different shapes and volumes: 2 × 2 × 1 mm, 2 × 2 × 2 mm, or 2 × 2 × 3 mm. The water surface ratio Sout/Sin is given as function of Vw/Vinc, which is the ratio of initial volume of water drop Vw to the volume of solid graphite inclusion Vinc. The study has shown that the maximum value of the ratio Sout/Sin ≈ 15 can be reached when Vw ∼ Vinc. When, the ratio of Sout/Sin varies in the range 1 to 15. The increase of the evaporating surface is of the highest interest to improve the heat transport and to be used and developed in heat technologies. Режим доступа: по договору с организацией-держателем ресурса |
| Język: | angielski |
| Wydane: |
2017
|
| Hasła przedmiotowe: | |
| Dostęp online: | https://doi.org/10.1016/j.applthermaleng.2017.08.162 |
| Format: | Elektroniczne Rozdział |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=656002 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 656002 | ||
| 005 | 20260804071557.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\22347 | ||
| 035 | |a RU\TPU\network\21880 | ||
| 090 | |a 656002 | ||
| 100 | |a 20171017d2017 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Breakup of heterogeneous water drop immersed in high-temperature air |f O. V. Vysokomornaya, M. V. Piskunov, P. A. Strizhak | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: p. 1345 (15 tit.)] | ||
| 330 | |a The enhancement of the evaporation rate of a heterogeneous water drop is experimentally investigated. A water drop encapsulating a solid graphite inclusion is instantaneously placed in the very hot air. Under action of the high ambient temperature and due to different thermal properties between water and solid inclusion, the initial drop explodes and creates numerous very small droplets. The vaporization rate of the water drop is strongly increased leading to a short time life of the drop. High speed video recording is used to detail the explosive breakup mechanism of a drop immersed in hot air when its temperature varies in the range between 1073 K and 1373 K. The target of the study is to determine the possible conditions for the increase of the water/air surface of the drop after breakup, i.e., the ratio of the final to initial surface, Sout/Sin, and to verify that this enlargement is responsible of the evaporation rate enhancement. For this purpose, we investigate drops of different initial volumes (5-15 µl) with graphite solid inclusions of different shapes and volumes: 2 × 2 × 1 mm, 2 × 2 × 2 mm, or 2 × 2 × 3 mm. The water surface ratio Sout/Sin is given as function of Vw/Vinc, which is the ratio of initial volume of water drop Vw to the volume of solid graphite inclusion Vinc. The study has shown that the maximum value of the ratio Sout/Sin ≈ 15 can be reached when Vw ∼ Vinc. When, the ratio of Sout/Sin varies in the range 1 to 15. The increase of the evaporating surface is of the highest interest to improve the heat transport and to be used and developed in heat technologies. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Applied Thermal Engineering | ||
| 463 | |t Vol. 127 |v [P. 1340-1345] |d 2017 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a водоугольные суспензии | |
| 610 | 1 | |a капли | |
| 610 | 1 | |a испарение | |
| 610 | 1 | |a зажигание | |
| 610 | 1 | |a графитовые частицы | |
| 700 | 1 | |a Vysokomornaya |b O. V. |c physicist |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences |f 1984- |g Olga Valeryevna |3 (RuTPU)RU\TPU\pers\33928 |9 17501 | |
| 701 | 1 | |a Piskunov |b M. V. |c specialist in the field of thermal engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences |f 1991- |g Maksim Vladimirovich |y Tomsk |3 (RuTPU)RU\TPU\pers\34151 |9 17691 | |
| 701 | 1 | |a Strizhak |b P. A. |c Specialist in the field of heat power energy |c Doctor of Physical and Mathematical Sciences (DSc), Professor of Tomsk Polytechnic University (TPU) |f 1985- |g Pavel Alexandrovich |3 (RuTPU)RU\TPU\pers\30871 |9 15117 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Энергетический институт (ЭНИН) |b Кафедра теоретической и промышленной теплотехники (ТПТ) |3 (RuTPU)RU\TPU\col\18679 |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Энергетический институт (ЭНИН) |b Кафедра автоматизации теплоэнергетических процессов (АТП) |3 (RuTPU)RU\TPU\col\18678 |
| 801 | 2 | |a RU |b 63413507 |c 20171017 |g RCR | |
| 856 | 4 | |u https://doi.org/10.1016/j.applthermaleng.2017.08.162 | |
| 942 | |c CF | ||