Sectioned calorimeter for quick diagnostic of the electron beam energy distribution; Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment; Vol. 875

Manylion Llyfryddiaeth
Parent link:Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Vol. 875.— 2017.— [P. 132-136]
Awdur Corfforaethol: Национальный исследовательский Томский политехнический университет
Awduron Eraill: Egorov I. S. Ivan Sergeevich, Serebrennikov M. A. Maksim Anatoljevich, Isakova Yu. I. Yulia Ivanovna, Poloskov A. V. Artem Viktorovich
Crynodeb:Title screen
This article presents a description of the principle, design and results of a calorimeter intended for recording the beam parameters of a pulsed electron accelerator. The collector of the calorimeter with a diameter of 100 mm has 61 separate sections. The sections are fixed in the base made of a material with low thermal conductivity. The temperature of each section was determined by analyzing the thermal image of the collector with an IR camera. The thickness and mass of the sections are designed for beams with the kinetic energy of electrons up to 700 keV at the energy density of up to 3 J/cm2. The calorimeter was tested on a pulsed electron accelerator “ASTRA-M” (450 kV, 1 kA, beam current duration 150 ns). When the electron beam was injected into the atmosphere, the accuracy of the measurements was reduced by 10%. The measurement for 10 s after a series of beam pulses did not lead to a significant variation in the results. The calorimeter is suitable for rapid evaluation of the beam energy distribution profiles when the beam is injected into the atmosphere without depressurizing the vacuum volume of the electron diode.
Режим доступа: по договору с организацией-держателем ресурса
Iaith:Saesneg
Cyhoeddwyd: 2017
Pynciau:
Mynediad Ar-lein:https://doi.org/10.1016/j.nima.2017.09.002
Fformat: Electronig Pennod Llyfr
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655876
Disgrifiad
Crynodeb:Title screen
This article presents a description of the principle, design and results of a calorimeter intended for recording the beam parameters of a pulsed electron accelerator. The collector of the calorimeter with a diameter of 100 mm has 61 separate sections. The sections are fixed in the base made of a material with low thermal conductivity. The temperature of each section was determined by analyzing the thermal image of the collector with an IR camera. The thickness and mass of the sections are designed for beams with the kinetic energy of electrons up to 700 keV at the energy density of up to 3 J/cm2. The calorimeter was tested on a pulsed electron accelerator “ASTRA-M” (450 kV, 1 kA, beam current duration 150 ns). When the electron beam was injected into the atmosphere, the accuracy of the measurements was reduced by 10%. The measurement for 10 s after a series of beam pulses did not lead to a significant variation in the results. The calorimeter is suitable for rapid evaluation of the beam energy distribution profiles when the beam is injected into the atmosphere without depressurizing the vacuum volume of the electron diode.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.1016/j.nima.2017.09.002