Matching a line to an explosive-emission diode in local therapy devices

Bibliographic Details
Parent link:Technical Physics Letters
Vol. 28, iss. 7.— 2001.— [P. 550-551]
Main Author: Mesyats G. A. Gennady Andreyevich
Summary:Title screen
It was previously suggested to use explosive-emission diodes generating X-ray pulses for local therapy purposes. The diode is usually powered by pulses supplied via a thin electrical cable. Effective operation of such a system requires that maximum pulsed energy transmitted via the cable would be absorbed in the diode. Taking into account nonlinearity of the current-voltage characteristic of the diode, it is impossible to ensure the line-to-diode matching in the general case. It is suggested to match the cable to the load by selecting a proper shape of the voltage pulse supplied to the diode. For an explosive-emission diode with flat electrodes, a virtually perfect matching is achieved with triangular voltage pulses.
Режим доступа: по договору с организацией-держателем ресурса
Language:English
Published: 2001
Subjects:
Online Access:http://dx.doi.org/10.1134/1.1498781
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655678

MARC

LEADER 00000naa0a2200000 4500
001 655678
005 20250328162612.0
035 |a (RuTPU)RU\TPU\network\21937 
035 |a RU\TPU\network\21931 
090 |a 655678 
100 |a 20170921d2002 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Matching a line to an explosive-emission diode in local therapy devices  |f G. A. Mesyats 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 551 (3 tit.)] 
330 |a It was previously suggested to use explosive-emission diodes generating X-ray pulses for local therapy purposes. The diode is usually powered by pulses supplied via a thin electrical cable. Effective operation of such a system requires that maximum pulsed energy transmitted via the cable would be absorbed in the diode. Taking into account nonlinearity of the current-voltage characteristic of the diode, it is impossible to ensure the line-to-diode matching in the general case. It is suggested to match the cable to the load by selecting a proper shape of the voltage pulse supplied to the diode. For an explosive-emission diode with flat electrodes, a virtually perfect matching is achieved with triangular voltage pulses. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Technical Physics Letters 
463 |t Vol. 28, iss. 7  |v [P. 550-551]  |d 2001 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a взрывчатые излучения 
610 1 |a диоды 
610 1 |a излучения 
610 1 |a электроды 
610 1 |a напряжение 
700 1 |a Mesyats  |b G. A.  |c russian physicist  |c academican, vice-president of RAS  |c graduate of Tomsk Polytechnic Institute  |f 1936-  |g Gennady Andreyevich  |3 (RuTPU)RU\TPU\pers\28088 
801 2 |a RU  |b 63413507  |c 20171011  |g RCR 
856 4 |u http://dx.doi.org/10.1134/1.1498781 
942 |c CF