Preserved boreal zone forest massif mass estimation during fire extinguishing by liquid aerosol

Bibliographic Details
Parent link:MATEC Web of Conferences
Vol. 110 : Heat and Mass Transfer in the Thermal Control System of Technical and Technological Energy Equipment (HMTTSC 2017).— 2017.— [01039, 6 p.]
Main Author: Shlegel N. E. Nikita Evgenjevich
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Лаборатория моделирования процессов тепломассопереноса (ЛМПТ)
Other Authors: Nyashina G. S. Galina Sergeevna, Zhdanova A. O. Alyona
Summary:Title screen
This study contains results of experimental studies into establishing the principles of decreasing the model of fire source mass when extinguishing the ground cover of deciduous and mixed forests by liquid aerosol. The experiments were carried out with typical forest fuels - birch leaves and mixed non-living components of temperate forest. Densities of forest fuel samples in a model of fire source were variated in the corresponding real practice ranges: 20.26–54.70 kg/m{3} for birch leaves and 27.54–72.18 kg/m{3} for a mixed forest fuel. Dimensions of droplets generated by the nozzle amounted to 0.01–0.12 mm. It is consistent with modern aerosol fire extinguishing systems. The dependence of the initial forest fuel sample mass on the remaining mass after ending of the pyrolysis reaction was established.
Published: 2017
Subjects:
Online Access:https://doi.org/10.1051/matecconf/201711001039
http://earchive.tpu.ru/handle/11683/42606
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655345