First beam test of a liquid Cherenkov detector prototype for a future TOF measurements at the Super-FRS; Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment; Vol. 866

Dades bibliogràfiques
Parent link:Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Vol. 866.— 2017.— [P. 207-212]
Autor corporatiu: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Кафедра экспериментальной физики (ЭФ)
Altres autors: Kuzminchuk-Feuerstein N. A. Natalia Aleksandrovna, Ferber N. Nadine, Fiks E. I. Elena Ivanovna, Kaufeld I. Ingo, Voss B. Bernd
Sumari:Title screen
In order to separate and identify fragmentation products with the Super-Fragment Separator (SuperFRS) at FAIR a high resolving power detector system is required for position and Time-Of-Flight (TOF) measurements. The TOF detector is used to measure the velocity of the particles and hence, in conjunction with their momentum or energy, to determine their mass and hence their identity. Aiming to develop a system with a precision down to about 50 ps in time and resistant to a high radiation rate of relativistic heavy ions of up to 107 per spill (at the second focal plane), we have shown a conceptual design for a Cherenkov detector envisioned for the future TOF measurements employing Iodine Naphthalene (C10H7I) as a fluid radiator. The application of a liquid radiator allows the circulation of the active material and therefore to greatly reduce the effects of the degradation of the optical performance expected after exposure to the high ion rates at the Super-FRS. The prototype of a TOF-Cherenkov detector was designed, constructed and its key-properties have been investigated in measurements with heavy ions at CaveC at GSI. These measurements were performed with nickel ions at 300-1500 MeV/u and ion-beam intensities of up to 4×106 ions/spill of 8 s. As a first result a maximum detection efficiency of 70% and a timing resolution of 267 ps (σ) was achieved. We report the first attempt of time measurements with a Cherenkov detector based on a liquid radiator. Further optimization is required.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:anglès
Publicat: 2017
Matèries:
Accés en línia:https://doi.org/10.1016/j.nima.2017.06.010
Format: Electrònic Capítol de llibre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655334

MARC

LEADER 00000naa0a2200000 4500
001 655334
005 20250318121741.0
035 |a (RuTPU)RU\TPU\network\21414 
090 |a 655334 
100 |a 20170830d2017 k||y0rusy50 ba 
101 0 |a eng 
102 |a NL 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a First beam test of a liquid Cherenkov detector prototype for a future TOF measurements at the Super-FRS  |f N. A. Kuzminchuk-Feuerstein [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 212 (28 tit.)] 
330 |a In order to separate and identify fragmentation products with the Super-Fragment Separator (SuperFRS) at FAIR a high resolving power detector system is required for position and Time-Of-Flight (TOF) measurements. The TOF detector is used to measure the velocity of the particles and hence, in conjunction with their momentum or energy, to determine their mass and hence their identity. Aiming to develop a system with a precision down to about 50 ps in time and resistant to a high radiation rate of relativistic heavy ions of up to 107 per spill (at the second focal plane), we have shown a conceptual design for a Cherenkov detector envisioned for the future TOF measurements employing Iodine Naphthalene (C10H7I) as a fluid radiator. The application of a liquid radiator allows the circulation of the active material and therefore to greatly reduce the effects of the degradation of the optical performance expected after exposure to the high ion rates at the Super-FRS. The prototype of a TOF-Cherenkov detector was designed, constructed and its key-properties have been investigated in measurements with heavy ions at CaveC at GSI. These measurements were performed with nickel ions at 300-1500 MeV/u and ion-beam intensities of up to 4×106 ions/spill of 8 s. As a first result a maximum detection efficiency of 70% and a timing resolution of 267 ps (σ) was achieved. We report the first attempt of time measurements with a Cherenkov detector based on a liquid radiator. Further optimization is required. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 
463 |t Vol. 866  |v [P. 207-212]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a черенковские детекторы 
610 1 |a тяжелые ионы 
610 1 |a время 
610 1 |a пролетные электроны 
701 1 |a Kuzminchuk-Feuerstein  |b N. A.  |g Natalia Aleksandrovna 
701 1 |a Ferber  |b N.  |g Nadine 
701 1 |a Fiks  |b E. I.  |c physicist  |c engineer-researcher of Tomsk Polytechnic University, candidate of physico-mathematical Sciences  |f 1988-  |g Elena Ivanovna  |3 (RuTPU)RU\TPU\pers\33634 
701 1 |a Kaufeld  |b I.  |g Ingo 
701 1 |a Voss  |b B.  |g Bernd 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Физико-технический институт (ФТИ)  |b Кафедра экспериментальной физики (ЭФ)  |3 (RuTPU)RU\TPU\col\21255 
801 2 |a RU  |b 63413507  |c 20170830  |g RCR 
856 4 |u https://doi.org/10.1016/j.nima.2017.06.010 
942 |c CF