Liver Hemostasis by Using Cold Plasma; Surgical Innovation; Vol. 24, iss. 3

Xehetasun bibliografikoak
Parent link:Surgical Innovation.— , 1994-
Vol. 24, iss. 3.— 2017.— [P. 253-258]
Erakunde egilea: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Кафедра прикладной физики (№ 12) (ПФ)
Beste egile batzuk: Aleinik A. N. Aleksandr Nikonorovich, Baikov A. N. Alexander Nikolaevich, Dambaev G. T. Georgiy Tsyrenovich, Semichev E. V. Evgeniy Vasiljevich, Bushlanov P. S. Pavel Sergeevich
Gaia:Title screen
Surgical resection is associated with blood loss and bacterial infections. The aim of this study was to evaluate the effectiveness of cold plasma treatment during liver resection. Thirty adult male Wistar rats were divided randomly into 2 groups. Group I was the control group—intact animals (5 in total). The second group (25 in total)—experimental animals—had atypical resection of the left lobe of the liver with subsequent coagulation by "nonequilibrium" plasma. Histological tissue samples, biochemical blood indices, and hemocoagulation parameters were investigated on 3, 5, 7, 14, and 30 days after plasma treatment. The sterilization test was made to investigate the plasma bactericidal effects. Cessation of bleeding took less than 1 minute. Blood loss was negligible. Morphometric analysis of the liver revealed increased number of hepatocytes with signs of dystrophy after surgical intervention, which returned to the baseline values after 30 days. Biochemical blood parameters revealed significant differences in the groups only in terms of glucose (P < .05); other parameters remained unchanged. High sterilization efficiency of cold plasma is confirmed. These results demonstrate the high efficiency of cold plasma treatment during surgical interventions.
Hizkuntza:ingelesa
Argitaratua: 2017
Gaiak:
Sarrera elektronikoa:http://dx.doi.org/10.1177/1553350617691710
Formatua: Baliabide elektronikoa Liburu kapitulua
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655248

MARC

LEADER 00000naa0a2200000 4500
001 655248
005 20250911140514.0
035 |a (RuTPU)RU\TPU\network\21193 
035 |a RU\TPU\network\18828 
090 |a 655248 
100 |a 20170814d2017 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Liver Hemostasis by Using Cold Plasma  |f A. N. Aleinik [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 257-258 (20 tit.)] 
330 |a Surgical resection is associated with blood loss and bacterial infections. The aim of this study was to evaluate the effectiveness of cold plasma treatment during liver resection. Thirty adult male Wistar rats were divided randomly into 2 groups. Group I was the control group—intact animals (5 in total). The second group (25 in total)—experimental animals—had atypical resection of the left lobe of the liver with subsequent coagulation by "nonequilibrium" plasma. Histological tissue samples, biochemical blood indices, and hemocoagulation parameters were investigated on 3, 5, 7, 14, and 30 days after plasma treatment. The sterilization test was made to investigate the plasma bactericidal effects. Cessation of bleeding took less than 1 minute. Blood loss was negligible. Morphometric analysis of the liver revealed increased number of hepatocytes with signs of dystrophy after surgical intervention, which returned to the baseline values after 30 days. Biochemical blood parameters revealed significant differences in the groups only in terms of glucose (P < .05); other parameters remained unchanged. High sterilization efficiency of cold plasma is confirmed. These results demonstrate the high efficiency of cold plasma treatment during surgical interventions. 
461 1 |t Surgical Innovation  |d 1994- 
463 1 |t Vol. 24, iss. 3  |v [P. 253-258]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a холодная плазма 
610 1 |a гемостаз 
610 1 |a стерилизация 
610 1 |a гистологический анализ 
701 1 |a Aleinik  |b A. N.  |c physicist  |c Senior researcher of Tomsk Polytechnic University, Candidate of physical and mathematical science  |f 1944-  |g Aleksandr Nikonorovich  |3 (RuTPU)RU\TPU\pers\31074 
701 1 |a Baikov  |b A. N.  |g Alexander Nikolaevich 
701 1 |a Dambaev  |b G. T.  |g Georgiy Tsyrenovich 
701 1 |a Semichev  |b E. V.  |g Evgeniy Vasiljevich 
701 1 |a Bushlanov  |b P. S.  |g Pavel Sergeevich 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Физико-технический институт (ФТИ)  |b Кафедра прикладной физики (№ 12) (ПФ)  |3 (RuTPU)RU\TPU\col\18729 
801 1 |a RU  |b 63413507  |c 20141010 
801 2 |a RU  |b 63413507  |c 20170814  |g RCR 
856 4 |u http://dx.doi.org/10.1177/1553350617691710 
942 |c CF