Оптимальное управление многомашинным комплексом системы поддержания пластового давления на нефтяных месторождениях; Нефтяное хозяйство; № 2

Бібліографічні деталі
Parent link:Нефтяное хозяйство: научно-технический производственный журнал.— , 1920-
№ 2.— 2017.— [С. 82-84]
Співавтор: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра электропривода и электрооборудования (ЭПЭО)
Інші автори: Сушков В. В., Велиев М. К., Тимошкин В. В. Вадим Владимирович, Гладких Т. Д.
Резюме:Заглавие с экрана
Technical condition of pumping units being reduced during operation as a consequence of normal wear exerts influence on electrical power consumed by the formation pressure maintenance system; it appears in increasing of electrical power losses in the pump. A method defining optimum structure of the operating pumping units have been developed to reduce electrical power losses caused by the technical condition of pumping units. The efficiency of the developed method to a large extent depends on accuracy of determination of the current technical condition of pumping units. A diagnostic system based upon the artificial neural network (ANN) and the database obtained from flow sensors of head and temperature at the pump outlet and inlet has been developed for assessing the technical condition of pumping units. For correct operation of the diagnostic system based upon the operation data, neural network training is conducted in order to set the weights between the neurons in such a way, that the INS output signal summary error tends towards zero. Training is executed in Matlab software environment using the Levenberg - Marquardt algorithm. Weights are adjusted depending on the value of the obtained error. Efficiency factors for two pumps ESP 500-1900 and one pump ESP 180-1900 have been defined using the developed diagnostic system based upon the operational data. The calculation results showed that the estimation error of the efficiency factor obtained using the suggested diagnostic system does not exceed 6 %.
Режим доступа: по договору с организацией-держателем ресурса
Мова:Російська
Опубліковано: 2017
Предмети:
Онлайн доступ:https://elibrary.ru/item.asp?id=28800904
Формат: Електронний ресурс Частина з книги
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655042

MARC

LEADER 00000naa0a2200000 4500
001 655042
005 20250314102009.0
035 |a (RuTPU)RU\TPU\network\20835 
035 |a RU\TPU\network\18975 
090 |a 655042 
100 |a 20170619d2017 k||y0rusy50 ca 
101 0 |a rus 
102 |a RU 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Оптимальное управление многомашинным комплексом системы поддержания пластового давления на нефтяных месторождениях  |d Optimum control for multiple computer complex of oil field formation pressure maintenance system  |f В. В. Сушков [и др.] 
203 |a Текст  |c электронный 
300 |a Заглавие с экрана 
320 |a [Библиогр.: с .84 (4 назв.)] 
330 |a Technical condition of pumping units being reduced during operation as a consequence of normal wear exerts influence on electrical power consumed by the formation pressure maintenance system; it appears in increasing of electrical power losses in the pump. A method defining optimum structure of the operating pumping units have been developed to reduce electrical power losses caused by the technical condition of pumping units. The efficiency of the developed method to a large extent depends on accuracy of determination of the current technical condition of pumping units. A diagnostic system based upon the artificial neural network (ANN) and the database obtained from flow sensors of head and temperature at the pump outlet and inlet has been developed for assessing the technical condition of pumping units. For correct operation of the diagnostic system based upon the operation data, neural network training is conducted in order to set the weights between the neurons in such a way, that the INS output signal summary error tends towards zero. Training is executed in Matlab software environment using the Levenberg - Marquardt algorithm. Weights are adjusted depending on the value of the obtained error. Efficiency factors for two pumps ESP 500-1900 and one pump ESP 180-1900 have been defined using the developed diagnostic system based upon the operational data. The calculation results showed that the estimation error of the efficiency factor obtained using the suggested diagnostic system does not exceed 6 %. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Нефтяное хозяйство  |o научно-технический производственный журнал  |d 1920- 
463 |t № 2  |v [С. 82-84]  |d 2017 
510 1 |a Optimum control for multiple computer complex of oil field formation pressure maintenance system  |z eng 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a насосные станции 
610 1 |a кустовые насосные станции 
610 1 |a энергетическая эффективность 
610 1 |a насосные агрегаты 
610 1 |a техническое состояние 
610 1 |a искусственные нейронные сети 
610 1 |a диагностические системы 
701 1 |a Сушков  |b В. В. 
701 1 |a Велиев  |b М. К. 
701 1 |a Тимошкин  |b В. В.  |c специалист в области электротехники  |c доцент Томского политехнического университета, кандидат технических наук  |f 1986-  |g Вадим Владимирович  |3 (RuTPU)RU\TPU\pers\26467  |9 12170 
701 1 |a Гладких  |b Т. Д. 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Энергетический институт (ЭНИН)  |b Кафедра электропривода и электрооборудования (ЭПЭО)  |3 (RuTPU)RU\TPU\col\18674 
801 2 |a RU  |b 63413507  |c 20170619  |g RCR 
856 4 0 |u https://elibrary.ru/item.asp?id=28800904 
942 |c CF