The second order polynomial load model impact on stability of the synchronous motor

Detalhes bibliográficos
Parent link:Industrial Engineering, Applications and Manufacturing (ICIEAM): Proceedings of 2nd International Conference, Chelyabinsk, May 19-20, 2016/ South Ural State University. [4 p.].— , 2016
Autor principal: Batseva N. L. Natalya Lenmirovna
Autor Corporativo: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра электрических сетей и электротехники (ЭСиЭ)
Outros Autores: Shuvalov A. Yu. Aleksey Yurjevich
Resumo:Title screen
The objective of this study is evaluation of the effect of the second order polynomial load model application for both voltage stability and transient stability analysis of the synchronous motor. For these purposes, the analytical method of obtaining the quadratic polynomial coefficients is developed and used for further test procedures. Researches of voltage stability are based on identification of the limited voltage value considering the constraints. Analysis of transient stability operates from behavior of the rotor angle in the time domain. The results demonstrate that the second polynomial load model must be recognized for both voltage stability and transient stability researches. The results are presented in tables and figures.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:inglês
Publicado em: 2016
Assuntos:
Acesso em linha:https://doi.org/10.1109/ICIEAM.2016.7911490
Formato: Recurso Electrónico Capítulo de Livro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=655010
Descrição
Resumo:Title screen
The objective of this study is evaluation of the effect of the second order polynomial load model application for both voltage stability and transient stability analysis of the synchronous motor. For these purposes, the analytical method of obtaining the quadratic polynomial coefficients is developed and used for further test procedures. Researches of voltage stability are based on identification of the limited voltage value considering the constraints. Analysis of transient stability operates from behavior of the rotor angle in the time domain. The results demonstrate that the second polynomial load model must be recognized for both voltage stability and transient stability researches. The results are presented in tables and figures.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.1109/ICIEAM.2016.7911490