4-kW multi-phase battery powered power supply; Journal of Physics: Conference Series; Vol. 830 : Energy Fluxes and Radiation Effects 2016
| Parent link: | Journal of Physics: Conference Series Vol. 830 : Energy Fluxes and Radiation Effects 2016.— 2017.— [012005, 5 p.] |
|---|---|
| Autor Corporativo: | |
| Outros Autores: | , , , , , |
| Resumo: | Title screen A method was developed for building the powerful battery power supplies. Using the method, the battery power supply with a 4 kW max power and up to 93% efficiency was developed to supply the "Yasen" X-ray apparatus. Two 60 Acenterdoth series-connected starter lead-acid batteries were used as a primary power supply. A DC output voltage of the source is stable over the entire power range and equals to 310 V. The power supply is based on a 5-phase HF-inverter. There is no difficulty in designing such power supplies with different power outputs. It can be done by the increasing or the decreasing number of phases (of inverter channels). This approach is not limited by the increased number of the inverter channels. The maximum output power will be determined by the battery characteristics only. The power supply is mounted on a mobile trolley, to increase the mobility of the entire set of equipment. The unit dimensions are 410•320•440, the weight is about 40 kg. The unit is forced air-cooled. A power operating mode is short and periodic. |
| Idioma: | inglês |
| Publicado em: |
2017
|
| Colecção: | High-current electronics |
| Assuntos: | |
| Acesso em linha: | http://dx.doi.org/10.1088/1742-6596/830/1/012005 http://earchive.tpu.ru/handle/11683/39471 |
| Formato: | Recurso Electrónico Capítulo de Livro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=654881 |
MARC
| LEADER | 00000nla2a2200000 4500 | ||
|---|---|---|---|
| 001 | 654881 | ||
| 005 | 20240212131818.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\20594 | ||
| 035 | |a RU\TPU\network\20513 | ||
| 090 | |a 654881 | ||
| 100 | |a 20170526a2017 k y0engy50 ba | ||
| 101 | 0 | |a eng | |
| 105 | |a y z 100zy | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a 4-kW multi-phase battery powered power supply |f A. V. Ponomarev [et al.] | |
| 203 | |a Text |c electronic | ||
| 225 | 1 | |a High-current electronics | |
| 300 | |a Title screen | ||
| 320 | |a [References: 2 tit.] | ||
| 330 | |a A method was developed for building the powerful battery power supplies. Using the method, the battery power supply with a 4 kW max power and up to 93% efficiency was developed to supply the "Yasen" X-ray apparatus. Two 60 Acenterdoth series-connected starter lead-acid batteries were used as a primary power supply. A DC output voltage of the source is stable over the entire power range and equals to 310 V. The power supply is based on a 5-phase HF-inverter. There is no difficulty in designing such power supplies with different power outputs. It can be done by the increasing or the decreasing number of phases (of inverter channels). This approach is not limited by the increased number of the inverter channels. The maximum output power will be determined by the battery characteristics only. The power supply is mounted on a mobile trolley, to increase the mobility of the entire set of equipment. The unit dimensions are 410•320•440, the weight is about 40 kg. The unit is forced air-cooled. A power operating mode is short and periodic. | ||
| 461 | 0 | |0 (RuTPU)RU\TPU\network\3526 |t Journal of Physics: Conference Series | |
| 463 | 0 | |0 (RuTPU)RU\TPU\network\20593 |t Vol. 830 : Energy Fluxes and Radiation Effects 2016 |o 5th International Congress, 2–7 October 2016, Tomsk, Russian Federation |o [materials] |f National Research Tomsk Polytechnic University (TPU) ; eds. M. V. Trigub G. E. Osokin ; A. S. Konovod |v [012005, 5 p.] |d 2017 | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a блоки питания | |
| 610 | 1 | |a источники питания | |
| 610 | 1 | |a рентгеновские аппараты | |
| 610 | 1 | |a инвенторы | |
| 610 | 1 | |a аккумуляторы | |
| 610 | 1 | |a батареи питания | |
| 610 | 1 | |a питание | |
| 701 | 1 | |a Ponomarev |b A. V. | |
| 701 | 1 | |a Korzhenevskiy |b S. R. | |
| 701 | 1 | |a Komarskiy |b А. A. | |
| 701 | 1 | |a Chepusov |b A. S. | |
| 701 | 1 | |a Mamontov |b Y. I. | |
| 701 | 1 | |a Ponomarev |b S. V. |c specialist in the field of industrial and medical electronics |c head of laboratory, Senior Lecturer of Tomsk Polytechnic University, candidate of technical Sciences |f 1958- |g Sergey Viktorovich |3 (RuTPU)RU\TPU\pers\35307 |9 18568 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт неразрушающего контроля (ИНК) |b Кафедра промышленной и медицинской электроники (ПМЭ) |3 (RuTPU)RU\TPU\col\18719 |
| 801 | 2 | |a RU |b 63413507 |c 20170620 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1088/1742-6596/830/1/012005 | |
| 856 | 4 | |u http://earchive.tpu.ru/handle/11683/39471 | |
| 942 | |c CF | ||