Corporate Authors: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра экологии и безопасности жизнедеятельности (ЭБЖ), Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра общей химии и химической технологии (ОХХТ)
Other Authors: Radenkov T. A. Timofey Aleksandrovich, Romanenko S. V. Sergey Vladimirovich, Kolpakov V. A. Valerii Aleksandrovich, Merzlyakov O. E., Kabanov V. A., Kagirov A. G. Arthur Gennagievich
Summary:Title screen
Corrosion monitoring methods and pH measuring devices are studied. Considering the heterogeneity of the soil pH, depending on depth and sampling points, it is advisable to use solid-state potentiometric sensors that are capable of pH measuring with an error not exceeding 0.2 pH units. In the process of the pipeline installation necessary to control the soil pH value. While it is impossible to predict what kind of horizon will be in contact with the pipe material at different points. This problem requires future development of technique for the correct pH measuring for the purpose of mobile pipeline corrosion monitoring. When using cathodic protection has been required find the balance between the parameters which prevent the corrosion reactions and also take into account the hydrogen absorption on surface of the pipes material.
Published: 2017
Subjects:
Online Access:http://dx.doi.org/10.1088/1757-899X/189/1/012030
http://earchive.tpu.ru/handle/11683/38500
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=654826
Description
Summary:Title screen
Corrosion monitoring methods and pH measuring devices are studied. Considering the heterogeneity of the soil pH, depending on depth and sampling points, it is advisable to use solid-state potentiometric sensors that are capable of pH measuring with an error not exceeding 0.2 pH units. In the process of the pipeline installation necessary to control the soil pH value. While it is impossible to predict what kind of horizon will be in contact with the pipe material at different points. This problem requires future development of technique for the correct pH measuring for the purpose of mobile pipeline corrosion monitoring. When using cathodic protection has been required find the balance between the parameters which prevent the corrosion reactions and also take into account the hydrogen absorption on surface of the pipes material.