Gaia:Title screen
One of the perspective directions of development of non-destructive testing is the method of computed tomography. Computed tomography really enhances the ability of X-ray inspection, from thin and simple to thick and complex parts. There are many factors that influence the performance of computed tomography, the main parameters for computed tomography scanners and also scanner based on betatron, are geometric magnification and spatial resolution. Calculations of these parameters for the betatron tomograph are shown in this paper.
Hizkuntza:ingelesa
Argitaratua: 2017
Gaiak:
Sarrera elektronikoa:http://dx.doi.org/10.1088/1757-899X/189/1/012022
http://earchive.tpu.ru/handle/11683/38509
Formatua: Baliabide elektronikoa Liburu kapitulua
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=654817

MARC

LEADER 00000nla2a2200000 4500
001 654817
005 20231222121302.0
035 |a (RuTPU)RU\TPU\network\20504 
035 |a RU\TPU\network\20500 
090 |a 654817 
100 |a 20170523a2017 k y0engy50 ba 
101 0 |a eng 
105 |a y z 100zy 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Calculation of Optimal Geometrical Magnification and Spatial Resolution of Betatron Tomograph  |f Y. Zhong, S. V. Chakhlov, V. B. Trinh 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 10 tit.] 
330 |a One of the perspective directions of development of non-destructive testing is the method of computed tomography. Computed tomography really enhances the ability of X-ray inspection, from thin and simple to thick and complex parts. There are many factors that influence the performance of computed tomography, the main parameters for computed tomography scanners and also scanner based on betatron, are geometric magnification and spatial resolution. Calculations of these parameters for the betatron tomograph are shown in this paper. 
461 0 |0 (RuTPU)RU\TPU\network\2008  |t IOP Conference Series: Materials Science and Engineering 
463 0 |0 (RuTPU)RU\TPU\network\20484  |t Vol. 189 : Modern Technologies for Non-Destructive Testing  |o 5th International Conference, 3–8 October 2016, Tomsk, Russian Federation  |o [proceedings]  |v [012022, 5 p.]  |d 2017 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a увеличение 
610 1 |a пространственное разрешение 
610 1 |a бетатроны 
610 1 |a томографы 
610 1 |a неразрушающий контроль 
610 1 |a компьютерная томография 
700 1 |a Zhong  |b Y. 
701 1 |a Chakhlov  |b S. V.  |c physicist  |c Head of the laboratory of Tomsk Polytechnic University, Candidate of physical and mathematical sciences  |f 1956-  |g Sergey Vladimirovich  |3 (RuTPU)RU\TPU\pers\34254  |9 17785 
701 1 |a Trinh  |b V. B. 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Российско-китайская научная лаборатория радиационного контроля и досмотра (РКНЛ РКД)  |3 (RuTPU)RU\TPU\col\21551 
801 2 |a RU  |b 63413507  |c 20170525  |g RCR 
856 4 |u http://dx.doi.org/10.1088/1757-899X/189/1/012022 
856 4 |u http://earchive.tpu.ru/handle/11683/38509 
942 |c CF