Ignition Characteristics of Coal-Water Slurry Containing Petrochemicals Based on Coal of Varying Degrees of Metamorphism; Energy and Fuels; Vol. 30, iss. 8

Bibliografiske detaljer
Parent link:Energy and Fuels
Vol. 30, iss. 8.— 2016.— [P. 6808-6816]
Hovedforfatter: Vershinina K. Yu. Kseniya Yurievna
Corporate Authors: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра автоматизации теплоэнергетических процессов (АТП), Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра теоретической и промышленной теплотехники (ТПТ)
Andre forfattere: Kuznetsov G. V. Geny Vladimirovich, Strizhak P. A. Pavel Alexandrovich
Summary:Title screen
This paper examines a coal–water slurry containing petrochemicals (CWSP) based on lignite, bituminous coal, anthracite, and typical waste—carbon residue obtained from the pyrolysis of tires. Waste motor oil is used as a liquid fuel component of the slurry. The study of CWSP ignition is performed via placing a fuel droplet on a low-inertia thermocouple junction (junction diameter is 0.1 mm; thermal inertia is less than 1 s) into the hot oxidant flow. The temperature and velocity of the oxidant flow vary in the range of 600–1200 K and 0.5–5 m/s, respectively. These ranges are typical for power plants in the large- and small-scale energy industry. The paper specifies the minimum oxidant temperatures which are sufficient for sustainable ignition, as well as the ignition delay times, the times for complete burnout of CWSP droplets (radii of 0.5–2 mm), and the maximum temperatures in the fuel combustion area. We discuss how the oxidant temperature and the component composition of CWSP influence the parameters listed above. Addition of a small amount of coal (with high content of volatiles) in a fuel composition can decrease the ignition temperature of CWSP based on bituminous coal and even anthracite by 50–150 K compared to that which is a traditional one for the energy sector. At the same time, the presence of coal of a high degree of metamorphism in CWSP leads to a substantial increase in the temperature in the fuel combustion zone, as well as in the duration of this process (as a result, more heat is released). The paper indicates the compositions which are characterized by minimum ignition lag, low temperature of ignition, and relatively high temperatures of combustion.
Режим доступа: по договору с организацией-держателем ресурса
Sprog:engelsk
Udgivet: 2016
Fag:
Online adgang:http://dx.doi.org/10.1021/acs.energyfuels.6b01016
Format: MixedMaterials Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=654654

MARC

LEADER 00000naa0a2200000 4500
001 654654
005 20250312160125.0
035 |a (RuTPU)RU\TPU\network\20295 
090 |a 654654 
100 |a 20170511d2016 k||y0rusy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Ignition Characteristics of Coal-Water Slurry Containing Petrochemicals Based on Coal of Varying Degrees of Metamorphism  |f K. Yu. Vershinina, G. V. Kuznetsov, P. A. Strizhak 
203 |a Text  |c electronic 
300 |a Title screen 
330 |a This paper examines a coal–water slurry containing petrochemicals (CWSP) based on lignite, bituminous coal, anthracite, and typical waste—carbon residue obtained from the pyrolysis of tires. Waste motor oil is used as a liquid fuel component of the slurry. The study of CWSP ignition is performed via placing a fuel droplet on a low-inertia thermocouple junction (junction diameter is 0.1 mm; thermal inertia is less than 1 s) into the hot oxidant flow. The temperature and velocity of the oxidant flow vary in the range of 600–1200 K and 0.5–5 m/s, respectively. These ranges are typical for power plants in the large- and small-scale energy industry. The paper specifies the minimum oxidant temperatures which are sufficient for sustainable ignition, as well as the ignition delay times, the times for complete burnout of CWSP droplets (radii of 0.5–2 mm), and the maximum temperatures in the fuel combustion area. We discuss how the oxidant temperature and the component composition of CWSP influence the parameters listed above. Addition of a small amount of coal (with high content of volatiles) in a fuel composition can decrease the ignition temperature of CWSP based on bituminous coal and even anthracite by 50–150 K compared to that which is a traditional one for the energy sector. At the same time, the presence of coal of a high degree of metamorphism in CWSP leads to a substantial increase in the temperature in the fuel combustion zone, as well as in the duration of this process (as a result, more heat is released). The paper indicates the compositions which are characterized by minimum ignition lag, low temperature of ignition, and relatively high temperatures of combustion. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Energy and Fuels 
463 |t Vol. 30, iss. 8  |v [P. 6808-6816]  |d 2016 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a водоугольное топливо 
610 1 |a суспензии 
610 1 |a нефтехимические продукты 
700 1 |a Vershinina  |b K. Yu.  |c specialist in the field of heat and power engineering  |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1992-  |g Kseniya Yurievna  |3 (RuTPU)RU\TPU\pers\33706  |9 17337 
701 1 |a Kuznetsov  |b G. V.  |c Specialist in the field of heat power energy  |c Professor of Tomsk Polytechnic University, Doctor of Physical and Mathematical Sciences  |f 1949-  |g Geny Vladimirovich  |3 (RuTPU)RU\TPU\pers\31891  |9 15963 
701 1 |a Strizhak  |b P. A.  |c Specialist in the field of heat power energy  |c Doctor of Physical and Mathematical Sciences (DSc), Professor of Tomsk Polytechnic University (TPU)  |f 1985-  |g Pavel Alexandrovich  |3 (RuTPU)RU\TPU\pers\30871  |9 15117 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Энергетический институт (ЭНИН)  |b Кафедра автоматизации теплоэнергетических процессов (АТП)  |3 (RuTPU)RU\TPU\col\18678 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Энергетический институт (ЭНИН)  |b Кафедра теоретической и промышленной теплотехники (ТПТ)  |3 (RuTPU)RU\TPU\col\18679 
801 2 |a RU  |b 63413507  |c 20170511  |g RCR 
856 4 |u http://dx.doi.org/10.1021/acs.energyfuels.6b01016 
942 |c CF