Polymethacrylate Matrix with Immobilized Acid–Base Indicators as pH Sensor; Procedia Engineering; Vol. 168 : Eurosensors 2016

מידע ביבליוגרפי
Parent link:Procedia Engineering
Vol. 168 : Eurosensors 2016.— 2016.— [P. 477–480]
מחבר תאגידי: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра экологии и безопасности жизнедеятельности (ЭБЖ)
מחברים אחרים: Sukhanov A. V. Aleksey Viktorovich, Ovsyannikova A. V. Anastasiya Vladimirovna, Gavrilenko N. A. Natalia Airatovna, Saranchina N. V. Nadezhda Vasilievna
סיכום:Title screen
The paper demonstrates possibility of using a polymethacrylate matrix(PMM) to the immobilization conventional volumetric pH indicators .Acid-base properties of the indicators immobilized into PMM were studied. It was found that immobilization of pH indicators into PMM led to changes in the absorption maximum of both basic and acidic forms of pH indicators. The pKa values of pH indicator immobilized into the PMM also changed in comparison with the solution. The immobilization of pH indicators into PMM enabled to extend its a pH indicating range compared with solution. The possibility of using a pH indicator immobilized into the PMM as pH sensors was shown.
שפה:אנגלית
יצא לאור: 2016
נושאים:
גישה מקוונת:http://dx.doi.org/10.1016/j.proeng.2016.11.134
פורמט: אלקטרוני Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=653589

MARC

LEADER 00000naa0a2200000 4500
001 653589
005 20250904095343.0
035 |a (RuTPU)RU\TPU\network\19072 
035 |a RU\TPU\network\18438 
090 |a 653589 
100 |a 20170316d2016 k||y0rusy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Polymethacrylate Matrix with Immobilized Acid–Base Indicators as pH Sensor  |f A. V. Sukhanov [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 480 (5 tit.)] 
330 |a The paper demonstrates possibility of using a polymethacrylate matrix(PMM) to the immobilization conventional volumetric pH indicators .Acid-base properties of the indicators immobilized into PMM were studied. It was found that immobilization of pH indicators into PMM led to changes in the absorption maximum of both basic and acidic forms of pH indicators. The pKa values of pH indicator immobilized into the PMM also changed in comparison with the solution. The immobilization of pH indicators into PMM enabled to extend its a pH indicating range compared with solution. The possibility of using a pH indicator immobilized into the PMM as pH sensors was shown. 
461 1 |t Procedia Engineering 
463 1 |t Vol. 168 : Eurosensors 2016  |o Proceedings of the 30th anniversary Eurosensors Conference, 4-7. Sepember 2016, Budapest, Hungary  |v [P. 477–480]  |d 2016 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a полиметакрилатные матрицы 
610 1 |a кислотно-основные показатели 
701 1 |a Sukhanov  |b A. V.  |c specialist in the field of scientific activity  |c Leading expert of Tomsk Polytechnic University, Candidate of chemical sciences  |f 1983-  |g Aleksey Viktorovich  |3 (RuTPU)RU\TPU\pers\31389  |9 15561 
701 1 |a Ovsyannikova  |b A. V.  |g Anastasiya Vladimirovna 
701 1 |a Gavrilenko  |b N. A.  |c chemist  |c Associate Professor of Tomsk Polytechnic University, Candidate of chemical sciences  |f 1970-  |g Natalia Airatovna  |3 (RuTPU)RU\TPU\pers\31394 
701 1 |a Saranchina  |b N. V.  |c chemist  |c Associate Professor of Tomsk Polytechnic University, Candidate of chemical sciences  |f 1982-  |g Nadezhda Vasilievna  |3 (RuTPU)RU\TPU\pers\31395  |9 15567 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Кафедра экологии и безопасности жизнедеятельности (ЭБЖ)  |3 (RuTPU)RU\TPU\col\18720 
801 2 |a RU  |b 63413507  |c 20170316  |g RCR 
856 4 |u http://dx.doi.org/10.1016/j.proeng.2016.11.134 
942 |c CF