Mathematical Simulation of the Transformer Differential Protection, Based on the Time-Impulse Principle

Մատենագիտական մանրամասներ
Parent link:MATEC Web of Conferences
Vol. 91 : Smart Grids 2017.— 2017.— [01048, 4 p.]
Համատեղ հեղինակ: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра электроэнергетических систем (ЭЭС)
Այլ հեղինակներ: Andreev M. V. Mikhail Vladimirovich, Borovikov Y. S. Yuri Sergeevich, Ruban N. Yu. Nikolay Yurievich, Khlebov A. V. Aleksey
Ամփոփում:Title screen
The modern electric power systems (EPS) are large, multi-parameter, stiff, non-linear and dynamic systems. Control and protection of such systems are extremely complex and urgent tasks. It is confirmed by the statistic of accidents in EPS: about 25 % of severe accidents are caused by wrong actions of relay protection (RP) and automation of EPS. The 30 % of these incorrect actions are caused by inadequate setting. The goal of this work is to solve the problem of RPs setting through the usage of detailed models that take into account specific features of the RPs and processes in transducers. The paper focused on the solution of the problem for the transformer differential protection (TDP), based on the impulse-time principle - DZT-21/DZT-23. The presented research results confirm the effectiveness of the usage of the appropriate mathematical models for the problem solution. The presented fragments are a part of a single project aimed at the problem' solution for all the RPs devices.
Հրապարակվել է: 2017
Խորագրեր:
Առցանց հասանելիություն:http://dx.doi.org/10.1051/matecconf/20179101048
http://earchive.tpu.ru/handle/11683/36635
Ձևաչափ: Էլեկտրոնային Գրքի գլուխ
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=652929
Նկարագրություն
Ամփոփում:Title screen
The modern electric power systems (EPS) are large, multi-parameter, stiff, non-linear and dynamic systems. Control and protection of such systems are extremely complex and urgent tasks. It is confirmed by the statistic of accidents in EPS: about 25 % of severe accidents are caused by wrong actions of relay protection (RP) and automation of EPS. The 30 % of these incorrect actions are caused by inadequate setting. The goal of this work is to solve the problem of RPs setting through the usage of detailed models that take into account specific features of the RPs and processes in transducers. The paper focused on the solution of the problem for the transformer differential protection (TDP), based on the impulse-time principle - DZT-21/DZT-23. The presented research results confirm the effectiveness of the usage of the appropriate mathematical models for the problem solution. The presented fragments are a part of a single project aimed at the problem' solution for all the RPs devices.
DOI:10.1051/matecconf/20179101048