Corrosion Effect on Concrete Barrier Life of a Decommissioned AD Reactor

Dades bibliogràfiques
Parent link:Atomic Energy
Vol. 121, iss. 1.— 2016.— [P. 49-55]
Autor principal: Antonenko M. V. Mikhail Viktorovich
Autor corporatiu: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра теоретической и промышленной теплотехники (ТПТ)
Altres autors: Chubreev D. O. Dmitry Olegovich, Kuznetsov G. V. Geny Vladimirovich
Sumari:Title screen
A mathematical model of diffusion of calcium hydroxide in the system concrete barrier–ambient environment was developed to determine the influence of corrosion processes of the first and second kinds, engendered by water and radionuclides, on the lifetime of a concrete barrier of a decommissioned commercial uranium-graphite reactor. The CaOH distribution over the thickness of the barrier in a single crack was determined. Calculations were performed to determine the CaOH concentration over the barrier thickness and to analyze the effect of corrosion and the use of S-3 superplasticizer in concrete on the lifetime of the barrier. The superplasticizer can extend the operating lifetime of the concrete barrier to 800 years.
Режим доступа: по договору с организацией-держателем ресурса
Idioma:anglès
Publicat: 2016
Matèries:
Accés en línia:http://dx.doi.org/10.1007/s10512-016-0160-5
Format: Electrònic Capítol de llibre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=652365

MARC

LEADER 00000naa0a2200000 4500
001 652365
005 20250331155607.0
035 |a (RuTPU)RU\TPU\network\17649 
090 |a 652365 
100 |a 20161220d2016 k||y0rusy50 ba 
101 1 |a eng 
102 |a US 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Corrosion Effect on Concrete Barrier Life of a Decommissioned AD Reactor  |f M. V. Antonenko, D. O. Chubreev, G. V. Kuznetsov 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 14 tit.] 
330 |a A mathematical model of diffusion of calcium hydroxide in the system concrete barrier–ambient environment was developed to determine the influence of corrosion processes of the first and second kinds, engendered by water and radionuclides, on the lifetime of a concrete barrier of a decommissioned commercial uranium-graphite reactor. The CaOH distribution over the thickness of the barrier in a single crack was determined. Calculations were performed to determine the CaOH concentration over the barrier thickness and to analyze the effect of corrosion and the use of S-3 superplasticizer in concrete on the lifetime of the barrier. The superplasticizer can extend the operating lifetime of the concrete barrier to 800 years. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Atomic Energy 
463 |t Vol. 121, iss. 1  |v [P. 49-55]  |d 2016 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a коррозии 
610 1 |a бетонные конструкции 
700 1 |a Antonenko  |b M. V.  |g Mikhail Viktorovich 
701 1 |a Chubreev  |b D. O.  |g Dmitry Olegovich 
701 1 |a Kuznetsov  |b G. V.  |c Specialist in the field of heat power energy  |c Professor of Tomsk Polytechnic University, Doctor of Physical and Mathematical Sciences  |f 1949-  |g Geny Vladimirovich  |3 (RuTPU)RU\TPU\pers\31891  |9 15963 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Энергетический институт (ЭНИН)  |b Кафедра теоретической и промышленной теплотехники (ТПТ)  |3 (RuTPU)RU\TPU\col\18679 
801 2 |a RU  |b 63413507  |c 20161220  |g RCR 
856 4 |u http://dx.doi.org/10.1007/s10512-016-0160-5 
942 |c CF