Simulation of fracture of the bone implant with the porous structure
| Parent link: | AIP Conference Proceedings Vol. 1760 : Physics of Cancer: Interdisciplinary Problems and Clinical Applications 2016.— 2016.— [020033, 4 p.] |
|---|---|
| Autor principal: | |
| Autor Corporativo: | |
| Outros Autores: | |
| Resumo: | Title screen Different approaches to bone defects reconstruction with the use of ceramic materials have been developed recently. Ceramics are identical with bone matrix, provide biomedical compatibility with bone tissue and possess high strength. But with an overall high strength ceramic implants destruct in dynamic mode. The paper presents a study of the effect of the porosity gradient on the destruction of the bone implants under dynamic loading. It is shown that the fracture behavior of the bone implants is changed with increasing levels of the gradient of porosity. Режим доступа: по договору с организацией-держателем ресурса |
| Publicado em: |
2016
|
| Assuntos: | |
| Acesso em linha: | http://dx.doi.org/10.1063/1.4960252 http://earchive.tpu.ru/handle/11683/35777 |
| Formato: | Recurso Electrónico Capítulo de Livro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=652001 |
MARC
| LEADER | 00000nla2a2200000 4500 | ||
|---|---|---|---|
| 001 | 652001 | ||
| 005 | 20231101134709.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\17264 | ||
| 035 | |a RU\TPU\network\17258 | ||
| 090 | |a 652001 | ||
| 100 | |a 20161129a2016 k y0engy50 ba | ||
| 101 | 0 | |a eng | |
| 105 | |a y z 100zy | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Simulation of fracture of the bone implant with the porous structure |f M. V. Korobenkov, S. N. Kulkov | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 5 tit.] | ||
| 330 | |a Different approaches to bone defects reconstruction with the use of ceramic materials have been developed recently. Ceramics are identical with bone matrix, provide biomedical compatibility with bone tissue and possess high strength. But with an overall high strength ceramic implants destruct in dynamic mode. The paper presents a study of the effect of the porosity gradient on the destruction of the bone implants under dynamic loading. It is shown that the fracture behavior of the bone implants is changed with increasing levels of the gradient of porosity. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | 0 | |0 (RuTPU)RU\TPU\network\4816 |t AIP Conference Proceedings | |
| 463 | 0 | |0 (RuTPU)RU\TPU\network\17033 |t Vol. 1760 : Physics of Cancer: Interdisciplinary Problems and Clinical Applications 2016 |o Proceedings of the International conference, 22-25 March 2016, Tomsk, Russia |f National Research Tomsk Polytechnic University (TPU) ; eds. E. Y. Gutmanas ; O. B. Naimark ; Yu. P. Sharkeev |v [020033, 4 p.] |d 2016 | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a моделирование | |
| 610 | 1 | |a переломы | |
| 610 | 1 | |a кости | |
| 610 | 1 | |a имплантанты | |
| 610 | 1 | |a пористые структуры | |
| 610 | 1 | |a дефекты | |
| 610 | 1 | |a керамика | |
| 610 | 1 | |a динамические нагрузки | |
| 700 | 1 | |a Korobenkov |b M. V. | |
| 701 | 1 | |a Kulkov |b S. N. |c specialist in the field of material science |c Professor of Tomsk Polytechnic University, Doctor of physical and mathematical sciences |f 1952- |g Sergey Nikolaevich |2 stltpush |3 (RuTPU)RU\TPU\pers\31428 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт физики высоких технологий (ИФВТ) |b Кафедра материаловедения в машиностроении (ММС) |h 74 |2 stltpush |3 (RuTPU)RU\TPU\col\18688 |
| 801 | 2 | |a RU |b 63413507 |c 20170120 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1063/1.4960252 | |
| 856 | 4 | |u http://earchive.tpu.ru/handle/11683/35777 | |
| 942 | |c CF | ||