Using the chemical dosimeter to measure the integral characteristics of the pulsed electron radiation

Dettagli Bibliografici
Parent link:11th International Forum on Strategic Technology (IFOST 2016): 1-3 June 2016, Novosibirsk, Russiain/ Novosibirsk State Technical University.— , 2016
Pt. 2.— 2016.— [P. 564-567]
Autore principale: Merinova L. R. Liliya Rashidovna
Enti autori: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Лаборатория № 1, Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра общей химии и химической технологии (ОХХТ)
Altri autori: Proskurina E. A. Elena Aleksandrovna, Shiyan L. N. Lyudmila Nikolaevna
Riassunto:Title screen
The paper presents the results on the study of the potassium nitrate dosimeter to estimate the characteristics of the pulsed electron radiation with an electron energy of 500 keV. One of the final products formed after potassium nitrate radiation is nitrite ion, whose radiation-chemical yield is constant and it equals 1.6 ion/100 eV. The measured concentration of nitrite ion with the Griess reagent enables to estimate the absorbed dose in any geometrical point of the irradiated volume. The comparable results of the magnitude of the absorbed dose obtained using a film dose color indicator are presented. The possibility to use an aqueous solution of potassium nitrate as a dosimeter, which is equivalent to the irradiated aqueous mediums, is studied. It is shown that the use of the potassium nitrate as a dosimeter is restricted due to the change in radiation-chemical yield of nitrite ions in solutions of different concentration.
Режим доступа: по договору с организацией-держателем ресурса
Lingua:inglese
Pubblicazione: 2016
Serie:Applied engineering
Soggetti:
Accesso online:http://dx.doi.org/10.1109/IFOST.2016.7884322
Natura: Elettronico Capitolo di libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=651373

MARC

LEADER 00000nla2a2200000 4500
001 651373
005 20240111111542.0
035 |a (RuTPU)RU\TPU\network\16622 
035 |a RU\TPU\network\16614 
090 |a 651373 
100 |a 20161110a2016 k y0rusy50 ba 
101 0 |a eng 
102 |a RU 
105 |a a z 101zy 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Using the chemical dosimeter to measure the integral characteristics of the pulsed electron radiation  |f L. R. Merinova, E. A. Proskurina, L. N. Shiyan 
203 |a Text  |c electronic 
225 1 |a Applied engineering 
300 |a Title screen 
320 |a [References: p. 567 (4 tit.)] 
330 |a The paper presents the results on the study of the potassium nitrate dosimeter to estimate the characteristics of the pulsed electron radiation with an electron energy of 500 keV. One of the final products formed after potassium nitrate radiation is nitrite ion, whose radiation-chemical yield is constant and it equals 1.6 ion/100 eV. The measured concentration of nitrite ion with the Griess reagent enables to estimate the absorbed dose in any geometrical point of the irradiated volume. The comparable results of the magnitude of the absorbed dose obtained using a film dose color indicator are presented. The possibility to use an aqueous solution of potassium nitrate as a dosimeter, which is equivalent to the irradiated aqueous mediums, is studied. It is shown that the use of the potassium nitrate as a dosimeter is restricted due to the change in radiation-chemical yield of nitrite ions in solutions of different concentration. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 1 |0 (RuTPU)RU\TPU\network\20157  |t 11th International Forum on Strategic Technology (IFOST 2016)  |o 1-3 June 2016, Novosibirsk, Russiain  |o in 2 pt.  |o [proceedings]  |f Novosibirsk State Technical University  |d 2016 
463 0 |0 (RuTPU)RU\TPU\network\20159  |t Pt. 2  |v [P. 564-567]  |d 2016 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a химические дозиметры 
610 1 |a импульсные электронные приборы 
610 1 |a нитрат калия 
610 1 |a водные растворы 
610 1 |a pulsed electron radiation 
610 1 |a dosimetry 
610 1 |a crystalline potassium nitrate dosimeter 
610 1 |a aqueous solution of potassium nitrate 
610 1 |a film dosimeter 
700 1 |a Merinova  |b L. R.  |c physicist  |c Associate Scientist of Tomsk Polytechnic University  |f 1981-  |g Liliya Rashidovna  |3 (RuTPU)RU\TPU\pers\32027  |9 16074 
701 1 |a Proskurina  |b E. A.  |g Elena Aleksandrovna 
701 1 |a Shiyan  |b L. N.  |c chemist  |c Associate Professor of Tomsk Polytechnic University, Candidate of physical and mathematical sciences  |f 1952-  |g Lyudmila Nikolaevna  |3 (RuTPU)RU\TPU\pers\31523 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт физики высоких технологий (ИФВТ)  |b Лаборатория № 1  |3 (RuTPU)RU\TPU\col\19035 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт физики высоких технологий (ИФВТ)  |b Кафедра общей химии и химической технологии (ОХХТ)  |3 (RuTPU)RU\TPU\col\21253 
801 2 |a RU  |b 63413507  |c 20171018  |g RCR 
856 4 |u http://dx.doi.org/10.1109/IFOST.2016.7884322 
942 |c CF