Pulsed Electron Beam Propagation in Oxygen; Key Engineering Materials; Vol. 712 : Advanced Materials for Technical and Medical Purpose (AMTMP 2016)

Dettagli Bibliografici
Parent link:Key Engineering Materials: Scientific Journal
Vol. 712 : Advanced Materials for Technical and Medical Purpose (AMTMP 2016).— 2016.— [P. 31-36]
Ente Autore: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Лаборатория № 1
Altri autori: Kholodnaya G. E. Galina Evgenievna, Sazonov R. V. Roman Vladimirovich, Ponomarev D. V. Denis Vladimirovich, Poloskov A. V. Artem Viktorovich
Riassunto:Title screen
The paper presents the results of the experimental investigation of the pulsed electron beam propagation propagated in a drift tube filled with oxygen. The pressure was 50, 300, and 760 Torr in the drift tube. The experiments were carried out using a TEA-500 pulsed electron accelerator (450 kV accelerating voltage; 10 kA electron beam current; 80±1 ns pulse duration to the base; up to 200 J pulse energy; and 5 cm diameter beam). The electron beam was propagated in the drift tube (40 cm long), 14 cm in diameter composed of two sections equipped with two reverse current shunts. The experiments were carried out which fixed the absorbed dose registered on the walls of the drift chamber.
Режим доступа: по договору с организацией-держателем ресурса
Lingua:inglese
Pubblicazione: 2016
Serie:Electrophysical and Electrochemical Methods and Technologies of Materials Treatment
Soggetti:
Accesso online:http://dx.doi.org/10.4028/www.scientific.net/KEM.712.31
Natura: Elettronico Capitolo di libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=651247
Descrizione
Riassunto:Title screen
The paper presents the results of the experimental investigation of the pulsed electron beam propagation propagated in a drift tube filled with oxygen. The pressure was 50, 300, and 760 Torr in the drift tube. The experiments were carried out using a TEA-500 pulsed electron accelerator (450 kV accelerating voltage; 10 kA electron beam current; 80±1 ns pulse duration to the base; up to 200 J pulse energy; and 5 cm diameter beam). The electron beam was propagated in the drift tube (40 cm long), 14 cm in diameter composed of two sections equipped with two reverse current shunts. The experiments were carried out which fixed the absorbed dose registered on the walls of the drift chamber.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.4028/www.scientific.net/KEM.712.31