Modelling Coal Combustion Conditions at its Storage in a Stack; MATEC Web of Conferences; Vol. 72 : Heat and Mass Transfer in the System of Thermal Modes of Energy – Technical and Technological Equipment (HMTTSC-2016)

Detalles Bibliográficos
Parent link:MATEC Web of Conferences
Vol. 72 : Heat and Mass Transfer in the System of Thermal Modes of Energy – Technical and Technological Equipment (HMTTSC-2016).— 2016.— [01064, 4 p.]
Autor principal: Masanik A. S.
Autor Corporativo: Национальный исследовательский Томский политехнический университет (ТПУ)
Otros Autores: Vasilevskiy A. V.
Sumario:Title screen
A mathematical model describing the heat and mass transfer processes during storage and ignition of coal stored in the stack, has been proposed. Numerical studies have allowed to determine the composition of gases and temperature profiles in the depth of the stack, depending on the air temperature and cloud cover. It was found that the cloudless hot weather (daytime temperatures of 303 K) within three days the top of the stack is heated to a temperature is its fire.
Lenguaje:inglés
Publicado: 2016
Materias:
Acceso en línea:http://dx.doi.org/10.1051/matecconf/20167201064
http://earchive.tpu.ru/handle/11683/33459
Formato: Electrónico Capítulo de libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=649932

MARC

LEADER 00000nla2a2200000 4500
001 649932
005 20231101134607.0
035 |a (RuTPU)RU\TPU\network\15102 
035 |a RU\TPU\network\15101 
090 |a 649932 
100 |a 20160831a2016 k y0engy50 ba 
101 0 |a eng 
105 |a y z 100zy 
135 |a drgn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Modelling Coal Combustion Conditions at its Storage in a Stack  |f A. S. Masanik, A. V. Vasilevskiy 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 2 tit.] 
330 |a A mathematical model describing the heat and mass transfer processes during storage and ignition of coal stored in the stack, has been proposed. Numerical studies have allowed to determine the composition of gases and temperature profiles in the depth of the stack, depending on the air temperature and cloud cover. It was found that the cloudless hot weather (daytime temperatures of 303 K) within three days the top of the stack is heated to a temperature is its fire. 
461 0 |0 (RuTPU)RU\TPU\network\4526  |t MATEC Web of Conferences 
463 0 |0 (RuTPU)RU\TPU\network\14977  |t Vol. 72 : Heat and Mass Transfer in the System of Thermal Modes of Energy – Technical and Technological Equipment (HMTTSC-2016)  |o April 19-21, 2016, Tomsk, Russia  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU) ; eds. G. V. Kuznetsov [et al.]  |v [01064, 4 p.]  |d 2016 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a сжигание 
610 1 |a угли 
610 1 |a математические модели 
610 1 |a тепломассоперенос 
610 1 |a массообмен 
610 1 |a газы 
610 1 |a стеки 
610 1 |a самовозгорание 
610 1 |a твердые топлива 
610 1 |a пожары 
700 1 |a Masanik  |b A. S. 
701 1 |a Vasilevskiy  |b A. V. 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |c (2009- )  |2 stltpush  |3 (RuTPU)RU\TPU\col\15902 
801 2 |a RU  |b 63413507  |c 20170120  |g RCR 
856 4 |u http://dx.doi.org/10.1051/matecconf/20167201064 
856 4 |u http://earchive.tpu.ru/handle/11683/33459 
942 |c CF