Stability enhancement of an integrated wind/solar system fed to an SG-based power system; Industry Applications Society, IAS 2015
| Источник: | Industry Applications Society, IAS 2015.— 2015.— [7 p.] |
|---|---|
| Автор-организация: | |
| Другие авторы: | , , , , |
| Примечания: | Title screen This paper proposes a new configuration to improve stability of an integrated wind/PV power generation system connected to a synchronous generator (SG)-based power system. Different renewable-energy power sources can be connected to the proposed common DC bus to constitute a flexible power-system configuration. The proposed control scheme uses a DC-to-AC inverter joined with a proportional-integral-derivative (PID) damping controller to contribute adequate damping characteristics to the dominant modes of the studied system under various operating conditions. A frequency-domain approach based on a linearized system model and a time-domain scheme based on a nonlinear system model subject to disturbances are systematically performed to examine the effectiveness of the proposed control scheme. Режим доступа: по договору с организацией-держателем ресурса |
| Язык: | английский |
| Опубликовано: |
2015
|
| Предметы: | |
| Online-ссылка: | http://dx.doi.org/10.1109/IAS.2015.7356926 |
| Формат: | Электронный ресурс Статья |
| Запись в KOHA: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=649716 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 649716 | ||
| 005 | 20250904160043.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\14878 | ||
| 090 | |a 649716 | ||
| 100 | |a 20160804d2015 k y0engy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Stability enhancement of an integrated wind/solar system fed to an SG-based power system |f L. Wang [et al.] | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 13 tit.] | ||
| 330 | |a This paper proposes a new configuration to improve stability of an integrated wind/PV power generation system connected to a synchronous generator (SG)-based power system. Different renewable-energy power sources can be connected to the proposed common DC bus to constitute a flexible power-system configuration. The proposed control scheme uses a DC-to-AC inverter joined with a proportional-integral-derivative (PID) damping controller to contribute adequate damping characteristics to the dominant modes of the studied system under various operating conditions. A frequency-domain approach based on a linearized system model and a time-domain scheme based on a nonlinear system model subject to disturbances are systematically performed to examine the effectiveness of the proposed control scheme. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 463 | |t Industry Applications Society, IAS 2015 |o the 50th Annual Meeting, October 18-22, 2015, Dallas, Texas |v [7 p.] |d 2015 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a энергия ветра | |
| 610 | 1 | |a демпфирование | |
| 701 | 1 | |a Wang |b L. |g Li | |
| 701 | 1 | |a Thi |b M. S. N. |g Mi Sa-Nguyen | |
| 701 | 1 | |a Truong |b D. N. |g Dinh-Nhon | |
| 701 | 1 | |a Prokhorov |b A. V. |c specialist in the field of electricity |c acting head, associate Professor, Deputy Director on educational work of Tomsk Polytechnic University, candidate of technical Sciences |f 1985- |g Anton Viktorovich |3 (RuTPU)RU\TPU\pers\32985 |9 16830 | |
| 701 | 1 | |a Ngo |b V. T. |g Van-Thuyen | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Энергетический институт (ЭНИН) |b Кафедра электрических сетей и электротехники (ЭСиЭ) |3 (RuTPU)RU\TPU\col\18677 |
| 801 | 2 | |a RU |b 63413507 |c 20160804 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1109/IAS.2015.7356926 | |
| 942 | |c CF | ||