Influence of air Gap Between the Transformer of Resistance and Object of Monitoring on Temperature Measurement Error; European Physical Journal Web of Conferences (EPJ Web of Conferences); Vol. 110 : Thermophysical Basis of Energy Technologies
| Parent link: | European Physical Journal Web of Conferences (EPJ Web of Conferences) Vol. 110 : Thermophysical Basis of Energy Technologies.— 2016.— [01041, 6 p.] |
|---|---|
| 1. Verfasser: | |
| Körperschaft: | |
| Weitere Verfasser: | |
| Zusammenfassung: | Title screen In operation the description of the developed heattransfer model in thermotransformers of resistance (RTD) in the conditions of air gap between surfaces of the sensor and object of measurement is provided. Research of influence of thickness of air gap on the relative error of temperature measurement by platinum, copper and nickel thermotransformers of resistance in the ranges of temperatures corresponding to each type is executed. Dependences of minimum necessary duration of heating up of sensors on the taken temperatures are received. |
| Sprache: | Englisch |
| Veröffentlicht: |
2016
|
| Schlagworte: | |
| Online-Zugang: | http://dx.doi.org/10.1051/epjconf/201611001041 http://earchive.tpu.ru/handle/11683/33376 |
| Format: | xMaterials Elektronisch Buchkapitel |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=647678 |
MARC
| LEADER | 00000nla2a2200000 4500 | ||
|---|---|---|---|
| 001 | 647678 | ||
| 005 | 20231227130644.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\12824 | ||
| 035 | |a RU\TPU\network\12822 | ||
| 090 | |a 647678 | ||
| 100 | |a 20160420a2016 k y0engy50 ba | ||
| 101 | 0 | |a eng | |
| 105 | |a y z 100zy | ||
| 135 | |a drgn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Influence of air Gap Between the Transformer of Resistance and Object of Monitoring on Temperature Measurement Error |f Yu. K. Atroshenko, A. A. Bychkova | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 10 tit.] | ||
| 330 | |a In operation the description of the developed heattransfer model in thermotransformers of resistance (RTD) in the conditions of air gap between surfaces of the sensor and object of measurement is provided. Research of influence of thickness of air gap on the relative error of temperature measurement by platinum, copper and nickel thermotransformers of resistance in the ranges of temperatures corresponding to each type is executed. Dependences of minimum necessary duration of heating up of sensors on the taken temperatures are received. | ||
| 461 | 0 | |0 (RuTPU)RU\TPU\network\7958 |t European Physical Journal Web of Conferences (EPJ Web of Conferences) | |
| 463 | 0 | |0 (RuTPU)RU\TPU\network\12773 |t Vol. 110 : Thermophysical Basis of Energy Technologies |o Proceedings of the Conference, October 13-15, 2015, Tomsk, Russia |f National Research Tomsk Polytechnic University (TPU) ; eds. G. V. Kuznetsov [et al.] |v [01041, 6 p.] |d 2016 | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a воздушные зазоры | |
| 610 | 1 | |a трансформаторы | |
| 610 | 1 | |a поверхности | |
| 700 | 1 | |a Atroshenko |b Yu. K. |c specialist in the field of power engineering |c Senior Lecturer of Tomsk Polytechnic University, Engineer |f 1989- |g Yuliana Konstantinovna |3 (RuTPU)RU\TPU\pers\32864 |9 16712 | |
| 701 | 1 | |a Bychkova |b A. A. | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Энергетический институт (ЭНИН) |b Кафедра автоматизации теплоэнергетических процессов (АТП) |3 (RuTPU)RU\TPU\col\18678 |
| 801 | 2 | |a RU |b 63413507 |c 20161121 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1051/epjconf/201611001041 | |
| 856 | 4 | 0 | |u http://earchive.tpu.ru/handle/11683/33376 |
| 942 | |c CF | ||