Insulation contamination of overhead transmission lines by extreme service conditions; IEEE Transactions on Dielectrics and Electrical Insulation; Vol. 23, iss. 1
| Parent link: | IEEE Transactions on Dielectrics and Electrical Insulation Vol. 23, iss. 1.— 2016.— [P. 288-293] |
|---|---|
| Автор: | |
| Співавтори: | , |
| Інші автори: | , |
| Резюме: | Title screen This paper investigates the specifications of suspended linear insulators under extremecontamination conditions: entrainments of agricultural chemical plants combined withalkaline soil dust. The authors outline the performance properties of insulators withalarge extended surface when contaminated by highly adhesive dust. The authors alsogive recommendations on the test procedure as well as the selection of optimal insulatorconfiguration for extreme service conditions. Режим доступа: по договору с организацией-держателем ресурса |
| Мова: | Англійська |
| Опубліковано: |
2016
|
| Предмети: | |
| Онлайн доступ: | http://dx.doi.org/10.1109/TDEI.2015.005323 |
| Формат: | Електронний ресурс Частина з книги |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=647474 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 647474 | ||
| 005 | 20250212094824.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\12614 | ||
| 090 | |a 647474 | ||
| 100 | |a 20160412d2016 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Insulation contamination of overhead transmission lines by extreme service conditions |f P. N. Bychkov, I. K. Zabrodina, V. S. Shlapak | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: p. 293 (13 tit.)] | ||
| 330 | |a This paper investigates the specifications of suspended linear insulators under extremecontamination conditions: entrainments of agricultural chemical plants combined withalkaline soil dust. The authors outline the performance properties of insulators withalarge extended surface when contaminated by highly adhesive dust. The authors alsogive recommendations on the test procedure as well as the selection of optimal insulatorconfiguration for extreme service conditions. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t IEEE Transactions on Dielectrics and Electrical Insulation | ||
| 463 | |t Vol. 23, iss. 1 |v [P. 288-293] |d 2016 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a изоляторы | |
| 610 | 1 | |a химическая промышленность | |
| 610 | 1 | |a воздушные линии электропередачи | |
| 610 | 1 | |a экстремальные условия | |
| 700 | 1 | |a Bychkov |b P. N. |c specialist in the field of nuclear power engineering |c Associate Professor of Tomsk Polytechnic University, Candidate of technical science |f 1957- |g Petr Nikolaevich |3 (RuTPU)RU\TPU\pers\34127 |9 17667 | |
| 701 | 1 | |a Zabrodina |b I. K. |c Linguist |c Associate Professor of Tomsk Polytechnic University, Candidate of pedagogical sciences |f 1983- |g Irina Konstantinovna |3 (RuTPU)RU\TPU\pers\35555 |9 18736 | |
| 701 | 1 | |a Shlapak |b V. S. |g Vladislav | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Физико-технический институт |b Кафедра экспериментальной физики |3 (RuTPU)RU\TPU\col\21255 |9 27946 |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет |b Институт развития стратегического партнерства и компетенций |b Кафедра методики преподавания иностранных языков |3 (RuTPU)RU\TPU\col\18976 |9 27280 |
| 801 | 2 | |a RU |b 63413507 |c 20160412 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1109/TDEI.2015.005323 | |
| 942 | |c CF | ||