Control of Cable Insulation Quality by Changing of Electrical Capacitance Per Unit During High Voltage Testing; Journal of Physics: Conference Series; Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015)
| Parent link: | Journal of Physics: Conference Series Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015).— 2016.— [012056, 4 p.] |
|---|---|
| Hlavní autor: | |
| Korporativní autor: | |
| Další autoři: | , |
| Shrnutí: | Title screen The paper describes the complex method of insulation quality control. It was found that electrical contact between bead chain electrodes and insulation surface can be provided by surface discharges along the entire length of the controlled zone. The pattern of electromagnetic field was developed by using Comsol Myltiphysics software. Режим доступа: по договору с организацией-держателем ресурса |
| Jazyk: | angličtina |
| Vydáno: |
2016
|
| Témata: | |
| On-line přístup: | http://dx.doi.org/10.1088/1742-6596/671/1/012056 http://earchive.tpu.ru/handle/11683/33763 |
| Médium: | Elektronický zdroj Kapitola |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=647216 |
MARC
| LEADER | 00000nla2a2200000 4500 | ||
|---|---|---|---|
| 001 | 647216 | ||
| 005 | 20231214092135.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\12354 | ||
| 035 | |a RU\TPU\network\12351 | ||
| 090 | |a 647216 | ||
| 100 | |a 20160329a2016 k y0engy50 ba | ||
| 101 | 0 | |a eng | |
| 105 | |a y z 100zy | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Control of Cable Insulation Quality by Changing of Electrical Capacitance Per Unit During High Voltage Testing |f N. S. Starikova, V. V. Redko, G. V. Vavilova | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 7 tit.] | ||
| 330 | |a The paper describes the complex method of insulation quality control. It was found that electrical contact between bead chain electrodes and insulation surface can be provided by surface discharges along the entire length of the controlled zone. The pattern of electromagnetic field was developed by using Comsol Myltiphysics software. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | 0 | |0 (RuTPU)RU\TPU\network\3526 |t Journal of Physics: Conference Series | |
| 463 | 0 | |0 (RuTPU)RU\TPU\network\12214 |t Vol. 671 : Innovations in Non-Destructive Testing (SibTest 2015) |o III All-Russian Scientific and Practical Conference, 27–31 July 2015, Altai, Russia |o [proceedings] |f National Research Tomsk Polytechnic University (TPU) |v [012056, 4 p.] |d 2016 | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a качество | |
| 610 | 1 | |a кабели | |
| 610 | 1 | |a электрическая емкость | |
| 610 | 1 | |a испытательные напряжения | |
| 610 | 1 | |a программное обеспечение | |
| 610 | 1 | |a Comsol Multiphysics | |
| 700 | 1 | |a Starikova |b N. S. |c specialist in the field of non-destructive testing |c Engineer of Tomsk Polytechnic University |f 1990- |g Nadezhda Sergeevna |3 (RuTPU)RU\TPU\pers\32605 |9 16518 | |
| 701 | 1 | |a Redko |b V. V. |c specialist in the field of non-destructive testing |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences |f 1974- |g Vitaliy Vladimirovich |3 (RuTPU)RU\TPU\pers\32887 |9 16735 | |
| 701 | 1 | |a Vavilova |b G. V. |c specialist in the field of non-destructive testing |c Head of Laboratory, Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences |f 1981- |g Galina Vasilievna |3 (RuTPU)RU\TPU\pers\32607 |9 16520 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт неразрушающего контроля (ИНК) |b Кафедра физических методов и приборов контроля качества (ФМПК) |3 (RuTPU)RU\TPU\col\18709 |
| 801 | 2 | |a RU |b 63413507 |c 20161125 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1088/1742-6596/671/1/012056 | |
| 856 | 4 | |u http://earchive.tpu.ru/handle/11683/33763 | |
| 942 | |c CF | ||