সংক্ষিপ্ত:Title screen
Ten different modulation methods of the isolated quasi Z-source inverter based DC-DC converter were tested to find out radiated emission levels. EMC measurements were performed on a low power 250 W prototype. A radiated emission test was carried out in a GTEM cell (gigahertz transverse electromagnetic cell) according to the EMC standard IEC 61000-4-20. To obtain a complete overview of the emissions, both C and D bands were included in a single test at the start and stop frequencies 30 MHz and 1 GHz, respectively. Measuring bandwidth of 120 kHz with a 6 dB EMI filter was used.
Режим доступа: по договору с организацией-держателем ресурса
ভাষা:ইংরেজি
প্রকাশিত: 2015
বিষয়গুলি:
অনলাইন ব্যবহার করুন:http://dx.doi.org/10.1109/PowerEng.2015.7266314
বিন্যাস: বৈদ্যুতিক গ্রন্থের অধ্যায়
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=647130

MARC

LEADER 00000naa0a2200000 4500
001 647130
005 20250617140900.0
035 |a (RuTPU)RU\TPU\network\12267 
035 |a RU\TPU\network\12051 
090 |a 647130 
100 |a 20160325d2015 k||y0rusy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Investigation of radiated emissions of a galvanically isolated qZS DC-DC converter  |f T. Jalakas [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 181 (10 tit.)] 
330 |a Ten different modulation methods of the isolated quasi Z-source inverter based DC-DC converter were tested to find out radiated emission levels. EMC measurements were performed on a low power 250 W prototype. A radiated emission test was carried out in a GTEM cell (gigahertz transverse electromagnetic cell) according to the EMC standard IEC 61000-4-20. To obtain a complete overview of the emissions, both C and D bands were included in a single test at the start and stop frequencies 30 MHz and 1 GHz, respectively. Measuring bandwidth of 120 kHz with a 6 dB EMI filter was used. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
463 |t 5th IEEE International Conference on Power Engineering, Energy and Electrical Drives: POWERENG, Riga, May 11-13, 2015  |o [proceedings]  |f Riga Technical University  |v [P. 176 - 181]  |d 2015 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Jalakas  |b T.  |g Tanel 
701 1 |a Jarkovoi  |b J.  |g Marek 
701 1 |a Roasto  |b I.  |g Indrek 
701 1 |a Zakis  |b J.  |g Janis 
701 1 |a Garganeev  |b A. G.  |c specialist in the field of electrical engineering  |c Professor of Tomsk Polytechnic University, doctor of technical Sciences  |f 1955-  |g Alexander Georgievich  |3 (RuTPU)RU\TPU\pers\35016 
712 0 2 |a Национальный исследовательский Томский политехнический университет  |c (2009- )  |9 26305 
801 2 |a RU  |b 63413507  |c 20160325  |g RCR 
850 |a 63413507 
856 4 |u http://dx.doi.org/10.1109/PowerEng.2015.7266314 
942 |c CF