Hydrogen Concentration Measurements at Titanium Layers by Means of Thermo-EMF; Key Engineering Materials; Vol. 683 : Multifunctional Materials: Development and Application

Бібліографічні деталі
Parent link:Key Engineering Materials: Scientific Journal
Vol. 683 : Multifunctional Materials: Development and Application.— 2016.— [P. 199-202]
Автор: Lider A. M. Andrey Markovich
Співавтор: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Кафедра общей физики (ОФ)
Інші автори: Larionov V. V. Vitaliy Vasilyevich, Syrtanov M. S. Maksim Sergeevich
Резюме:Title screen
The thermo-emf and electrical resistivity of hydrogenated titanium were measured. Hydrogen concentration in titanium varies from 0.005 to 0.25%. We have compared the methods regarding their sensitivity to the alteration of thermo-emf and electrical resistivity during titanium hydrogenation. The accuracy of the obtained results was verified by comparing them with the results for palladium. It was demonstrated that the method implementing thermo-emf is sensitive to hydrogen concentration in titanium at different depth of the alloy. On the basis of performed measurements, we have proposed a graphical method for detecting the change in titanium structure.
Режим доступа: по договору с организацией-держателем ресурса
Мова:Англійська
Опубліковано: 2016
Серія:Physicochemical Properties of Materials and Current Processing Technologies
Предмети:
Онлайн доступ:http://dx.doi.org/10.4028/www.scientific.net/KEM.683.199
Формат: Електронний ресурс Частина з книги
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646607
Опис
Резюме:Title screen
The thermo-emf and electrical resistivity of hydrogenated titanium were measured. Hydrogen concentration in titanium varies from 0.005 to 0.25%. We have compared the methods regarding their sensitivity to the alteration of thermo-emf and electrical resistivity during titanium hydrogenation. The accuracy of the obtained results was verified by comparing them with the results for palladium. It was demonstrated that the method implementing thermo-emf is sensitive to hydrogen concentration in titanium at different depth of the alloy. On the basis of performed measurements, we have proposed a graphical method for detecting the change in titanium structure.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.4028/www.scientific.net/KEM.683.199