Mobile Electric-Discharge Blasting Unit for Splitting off and Destruction of Rocks and Concrete

Bibliographic Details
Parent link:Key Engineering Materials: Scientific Journal
Vol. 685 : High Technology: Research and Applications 2015 (HTRA 2015).— 2016.— [P. 705-709]
Main Author: Voitenko N. V. Nikita Valerievich
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра сильноточной электроники (СЭ)
Other Authors: Yudin A. S. Artem Sergeevich
Summary:Title screen
The article describes the pulse power system for electric-discharge blasting of rocks and concrete, the main equipment of which is a high current pulse generator with operating voltage up to 15 kV. The test of short-circuit experiment was produced, the main parameters of the discharge circuit L=1.01 [mu]H, R=9 m[omega] were calculated. Based on the results of the experiments the impedance Z=42.5 m[omega] of discharge circuit was defined. The pulse power system with mentioned parameters has maximum power condition deviation of about 8.6 %.
Режим доступа: по договору с организацией-держателем ресурса
Published: 2016
Series:Discharge and Plasma-Beam Technology
Subjects:
Online Access:http://dx.doi.org/10.4028/www.scientific.net/KEM.685.705
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646521

MARC

LEADER 00000nla2a2200000 4500
001 646521
005 20250514111021.0
035 |a (RuTPU)RU\TPU\network\11657 
035 |a RU\TPU\network\11652 
090 |a 646521 
100 |a 20160302a2016 k y0engy50 ba 
101 0 |a eng 
105 |a y z 100zy 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Mobile Electric-Discharge Blasting Unit for Splitting off and Destruction of Rocks and Concrete  |f N. V. Voitenko, A. S. Yudin 
203 |a Text  |c electronic 
225 1 |a Discharge and Plasma-Beam Technology 
300 |a Title screen 
330 |a The article describes the pulse power system for electric-discharge blasting of rocks and concrete, the main equipment of which is a high current pulse generator with operating voltage up to 15 kV. The test of short-circuit experiment was produced, the main parameters of the discharge circuit L=1.01 [mu]H, R=9 m[omega] were calculated. Based on the results of the experiments the impedance Z=42.5 m[omega] of discharge circuit was defined. The pulse power system with mentioned parameters has maximum power condition deviation of about 8.6 %. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 0 |0 (RuTPU)RU\TPU\network\11477  |t Key Engineering Materials  |o Scientific Journal 
463 0 |0 (RuTPU)RU\TPU\network\11478  |t Vol. 685 : High Technology: Research and Applications 2015 (HTRA 2015)  |o The IV International Conference, April 21-24, 2015, Tomsk, Russia  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU) ; ed. N. V. Martyushev, A. M. Bogdan  |v [P. 705-709]  |d 2016 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a импульсные генераторы 
610 1 |a генераторы 
610 1 |a ток 
610 1 |a плазменные каналы 
610 1 |a разрушение 
610 1 |a горные породы 
610 1 |a бетоны 
610 1 |a электрические разряды 
700 1 |a Voitenko  |b N. V.  |c specialist in the field of electrophysics  |c engineer of Tomsk Polytechnic University  |f 1989-  |g Nikita Valerievich  |3 (RuTPU)RU\TPU\pers\33776 
701 1 |a Yudin  |b A. S.  |c specialist in the field of electrophysics  |c researcher of Tomsk Polytechnic University, candidate of technical sciences  |f 1984-  |g Artem Sergeevich  |3 (RuTPU)RU\TPU\pers\33778  |9 17376 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт физики высоких технологий (ИФВТ)  |b Кафедра сильноточной электроники (СЭ)  |3 (RuTPU)RU\TPU\col\18691 
801 2 |a RU  |b 63413507  |c 20160302  |g RCR 
850 |a 63413507 
856 4 |u http://dx.doi.org/10.4028/www.scientific.net/KEM.685.705 
942 |c CF