Mobile Electric-Discharge Blasting Unit for Splitting off and Destruction of Rocks and Concrete; Key Engineering Materials; Vol. 685 : High Technology: Research and Applications 2015 (HTRA 2015)

Bibliographische Detailangaben
Parent link:Key Engineering Materials: Scientific Journal
Vol. 685 : High Technology: Research and Applications 2015 (HTRA 2015).— 2016.— [P. 705-709]
1. Verfasser: Voitenko N. V. Nikita Valerievich
Körperschaft: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра сильноточной электроники (СЭ)
Weitere Verfasser: Yudin A. S. Artem Sergeevich
Zusammenfassung:Title screen
The article describes the pulse power system for electric-discharge blasting of rocks and concrete, the main equipment of which is a high current pulse generator with operating voltage up to 15 kV. The test of short-circuit experiment was produced, the main parameters of the discharge circuit L=1.01 [mu]H, R=9 m[omega] were calculated. Based on the results of the experiments the impedance Z=42.5 m[omega] of discharge circuit was defined. The pulse power system with mentioned parameters has maximum power condition deviation of about 8.6 %.
Режим доступа: по договору с организацией-держателем ресурса
Sprache:Englisch
Veröffentlicht: 2016
Schriftenreihe:Discharge and Plasma-Beam Technology
Schlagworte:
Online-Zugang:http://dx.doi.org/10.4028/www.scientific.net/KEM.685.705
Format: Elektronisch Buchkapitel
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646521
Beschreibung
Zusammenfassung:Title screen
The article describes the pulse power system for electric-discharge blasting of rocks and concrete, the main equipment of which is a high current pulse generator with operating voltage up to 15 kV. The test of short-circuit experiment was produced, the main parameters of the discharge circuit L=1.01 [mu]H, R=9 m[omega] were calculated. Based on the results of the experiments the impedance Z=42.5 m[omega] of discharge circuit was defined. The pulse power system with mentioned parameters has maximum power condition deviation of about 8.6 %.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.4028/www.scientific.net/KEM.685.705