Development of a method for testing the concentration of air voids in concrete based on the parameters of the electrical response to impact

Bibliographic Details
Parent link:Russian Journal of Nondestructive Testing
Vol. 51, iss. 10.— 2015.— [P. 597-600]
Main Author: Fursa T. V. Tatyana Viktorovna
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)
Other Authors: Dann D. D. Denis Dmitrievich
Summary:Title screen
The correlation between the concentration of defects such as artificial air voids in concrete and the parameters of the electrical response to impact was examined. It was shown that the frequency shift that corresponds to the maximum cross-correlation coefficient between the spectra of electrical responses of defective and non-defective samples may be used as a diagnostic criterion for determining the concentration of air voids in concrete.
Режим доступа: по договору с организацией-держателем ресурса
Language:English
Published: 2015
Series:Electrical Methods
Subjects:
Online Access:http://dx.doi.org/10.1134/S1061830915100046
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646376

MARC

LEADER 00000nla0a2200000 4500
001 646376
005 20250403113040.0
035 |a (RuTPU)RU\TPU\network\11512 
090 |a 646376 
100 |a 20160226d2015 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Development of a method for testing the concentration of air voids in concrete based on the parameters of the electrical response to impact  |f T. V. Fursa, D. D. Dann 
203 |a Text  |c electronic 
225 1 |a Electrical Methods 
300 |a Title screen 
320 |a [References: p. 600 (9 tit.)] 
330 |a The correlation between the concentration of defects such as artificial air voids in concrete and the parameters of the electrical response to impact was examined. It was shown that the frequency shift that corresponds to the maximum cross-correlation coefficient between the spectra of electrical responses of defective and non-defective samples may be used as a diagnostic criterion for determining the concentration of air voids in concrete. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Russian Journal of Nondestructive Testing 
463 |t Vol. 51, iss. 10  |v [P. 597-600]  |d 2015 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a неразрушающий контроль 
610 1 |a электрический отклик 
610 1 |a ударное возбуждение 
610 1 |a амплитудно-частотные характеристики 
700 1 |a Fursa  |b T. V.  |c specialist in the field of non-destructive testing  |c Leading researcher of Tomsk Polytechnic University, Doctor of technical sciences  |f 1951-  |g Tatyana Viktorovna  |3 (RuTPU)RU\TPU\pers\32190 
701 1 |a Dann  |b D. D.  |c specialist in the field of electrical engineering  |c Engineer-researcher of Tomsk Polytechnic University  |f 1987-  |g Denis Dmitrievich  |3 (RuTPU)RU\TPU\pers\32192 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП)  |3 (RuTPU)RU\TPU\col\19033 
801 2 |a RU  |b 63413507  |c 20161109  |g RCR 
856 4 |u http://dx.doi.org/10.1134/S1061830915100046 
942 |c CF