Development of a method for testing the concentration of air voids in concrete based on the parameters of the electrical response to impact
| Parent link: | Russian Journal of Nondestructive Testing Vol. 51, iss. 10.— 2015.— [P. 597-600] |
|---|---|
| Main Author: | |
| Corporate Author: | |
| Other Authors: | |
| Summary: | Title screen The correlation between the concentration of defects such as artificial air voids in concrete and the parameters of the electrical response to impact was examined. It was shown that the frequency shift that corresponds to the maximum cross-correlation coefficient between the spectra of electrical responses of defective and non-defective samples may be used as a diagnostic criterion for determining the concentration of air voids in concrete. Режим доступа: по договору с организацией-держателем ресурса |
| Language: | English |
| Published: |
2015
|
| Series: | Electrical Methods |
| Subjects: | |
| Online Access: | http://dx.doi.org/10.1134/S1061830915100046 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=646376 |
MARC
| LEADER | 00000nla0a2200000 4500 | ||
|---|---|---|---|
| 001 | 646376 | ||
| 005 | 20250403113040.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\11512 | ||
| 090 | |a 646376 | ||
| 100 | |a 20160226d2015 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drnn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Development of a method for testing the concentration of air voids in concrete based on the parameters of the electrical response to impact |f T. V. Fursa, D. D. Dann | |
| 203 | |a Text |c electronic | ||
| 225 | 1 | |a Electrical Methods | |
| 300 | |a Title screen | ||
| 320 | |a [References: p. 600 (9 tit.)] | ||
| 330 | |a The correlation between the concentration of defects such as artificial air voids in concrete and the parameters of the electrical response to impact was examined. It was shown that the frequency shift that corresponds to the maximum cross-correlation coefficient between the spectra of electrical responses of defective and non-defective samples may be used as a diagnostic criterion for determining the concentration of air voids in concrete. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Russian Journal of Nondestructive Testing | ||
| 463 | |t Vol. 51, iss. 10 |v [P. 597-600] |d 2015 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a неразрушающий контроль | |
| 610 | 1 | |a электрический отклик | |
| 610 | 1 | |a ударное возбуждение | |
| 610 | 1 | |a амплитудно-частотные характеристики | |
| 700 | 1 | |a Fursa |b T. V. |c specialist in the field of non-destructive testing |c Leading researcher of Tomsk Polytechnic University, Doctor of technical sciences |f 1951- |g Tatyana Viktorovna |3 (RuTPU)RU\TPU\pers\32190 | |
| 701 | 1 | |a Dann |b D. D. |c specialist in the field of electrical engineering |c Engineer-researcher of Tomsk Polytechnic University |f 1987- |g Denis Dmitrievich |3 (RuTPU)RU\TPU\pers\32192 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт неразрушающего контроля (ИНК) |b Проблемная научно-исследовательская лаборатория электроники, диэлектриков и полупроводников (ПНИЛ ЭДиП) |3 (RuTPU)RU\TPU\col\19033 |
| 801 | 2 | |a RU |b 63413507 |c 20161109 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1134/S1061830915100046 | |
| 942 | |c CF | ||