Ultrasonic IR thermographic inspection of graphite epoxy composite: a comparative study of piezoelectric and magnetostrictive stimulation; Opto-electronics review; Vol. 23, iss. 1

Bibliografiske detaljer
Parent link:Opto-electronics review: Scientific Journal.— , 1996-
Vol. 23, iss. 1.— 2015.— [P. 33-36]
Hovedforfatter: Swiderski W.
Institution som forfatter: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Лаборатория № 34 (Тепловых методов контроля)
Andre forfattere: Vavilov V. P. Vladimir Platonovich
Summary:Title screen
In this paper the experimental results of piezoelectric and magnetostrictive ultrasonic stimulation are comparatively analyzed in the evaluation of impact damage in a graphite epoxy composite sample chosen for a round robin test. By comparing theoretical and experimental results, it is shown that the equivalent power of internal friction can reach some hundreds mill watt per a single crack.
Режим доступа: по договору с организацией-держателем ресурса
Sprog:engelsk
Udgivet: 2015
Fag:
Online adgang:http://dx.doi.org/10.1515/oere-2015-0009
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=645823

MARC

LEADER 00000nla0a2200000 4500
001 645823
005 20250328144446.0
035 |a (RuTPU)RU\TPU\network\10927 
035 |a RU\TPU\network\10924 
090 |a 645823 
100 |a 20160127d2015 k||y0rusy50 ba 
101 0 |a eng 
102 |a PL 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Ultrasonic IR thermographic inspection of graphite epoxy composite: a comparative study of piezoelectric and magnetostrictive stimulation  |f W. Swiderski, V. P. Vavilov 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 36 (15 tit.)] 
330 |a In this paper the experimental results of piezoelectric and magnetostrictive ultrasonic stimulation are comparatively analyzed in the evaluation of impact damage in a graphite epoxy composite sample chosen for a round robin test. By comparing theoretical and experimental results, it is shown that the equivalent power of internal friction can reach some hundreds mill watt per a single crack. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Opto-electronics review  |o Scientific Journal  |d 1996- 
463 |t Vol. 23, iss. 1  |v [P. 33-36]  |d 2015 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a эпоксидные смолы 
610 1 |a графит 
610 1 |a ИК-термография 
610 1 |a дефектоскопия 
700 1 |a Swiderski  |b W. 
701 1 |a Vavilov  |b V. P.  |c Specialist in the field of dosimetry and methodology of nondestructive testing (NDT)  |c Doctor of technical sciences (DSc), Professor of Tomsk Polytechnic University (TPU)  |f 1949-  |g Vladimir Platonovich  |3 (RuTPU)RU\TPU\pers\32161  |9 16163 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт неразрушающего контроля (ИНК)  |b Лаборатория № 34 (Тепловых методов контроля)  |3 (RuTPU)RU\TPU\col\19616 
801 2 |a RU  |b 63413507  |c 20160127  |g RCR 
856 4 |u http://dx.doi.org/10.1515/oere-2015-0009 
942 |c CF