Laboratory Evaluation of the Drag Reduction Additives Effectiveness

Chi tiết về thư mục
Parent link:Procedia Chemistry
Vol. 15 : Chemistry and Chemical Engineering in XXI century (CCE 2015).— 2015.— [P. 371-377]
Nhiều tác giả của công ty: Национальный исследовательский Томский политехнический университет (ТПУ) Институт природных ресурсов (ИПР) Кафедра физической и аналитической химии (ФАХ), Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра общей химии и химической технологии (ОХХТ)
Tác giả khác: Nesyn G. V. Georgi, Konovalov K. B. Konstantin Borisovich, Vetrova O. V. Olga, Menshov P. Pavel
Tóm tắt:Title screen
This study describes the laboratory evaluation methodology of the drag reducing effect of block poly-1-octene. Poly-1-octene, synthesized in our laboratory was chosen as an object of the present study. To confirm the nature and the structure of the obtained polymer its FTIR spectrum was registered. The molecular mass was determined by viscosimetric method using an Ubellode viscosimeter, the obtained value was 5.22×10{6}. Hydrodynamic testing of poly-1-octene solutions has been performed using a capillary rheometer of our own construction for the quantitative estimation of the polymer's drag reduction capability. We introduce criterion for a quantitative estimation of a polymer hydrodynamic drag reducing capability. This is a semi-effect concentration С[1/2] that can be determined using a dependence of DR on the concentration.
Режим доступа: по договору с организацией-держателем ресурса
Được phát hành: 2015
Những chủ đề:
Truy cập trực tuyến:http://dx.doi.org/10.1016/j.proche.2015.10.059
http://earchive.tpu.ru/handle/11683/15080
Định dạng: Điện tử Chương của sách
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=645415
Miêu tả
Tóm tắt:Title screen
This study describes the laboratory evaluation methodology of the drag reducing effect of block poly-1-octene. Poly-1-octene, synthesized in our laboratory was chosen as an object of the present study. To confirm the nature and the structure of the obtained polymer its FTIR spectrum was registered. The molecular mass was determined by viscosimetric method using an Ubellode viscosimeter, the obtained value was 5.22×10{6}. Hydrodynamic testing of poly-1-octene solutions has been performed using a capillary rheometer of our own construction for the quantitative estimation of the polymer's drag reduction capability. We introduce criterion for a quantitative estimation of a polymer hydrodynamic drag reducing capability. This is a semi-effect concentration С[1/2] that can be determined using a dependence of DR on the concentration.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.1016/j.proche.2015.10.059