A colorimetric sensor based on a polymethacrylate matrix with immobilized 1-(2-pyridylazo)-2-naphthol for the determination of cobalt; Journal of Analytical Chemistry; Vol. 70, iss. 12

Bibliografische gegevens
Parent link:Journal of Analytical Chemistry: Scientific Journal
Vol. 70, iss. 12.— 2015.— [P. 1475-1479]
Hoofdauteur: Gavrilenko N. A. Natalia Airatovna
Coauteurs: Национальный исследовательский Томский политехнический университет (ТПУ) Институт неразрушающего контроля (ИНК) Кафедра экологии и безопасности жизнедеятельности (ЭБЖ), Национальный исследовательский Томский политехнический университет (ТПУ) Институт природных ресурсов (ИПР) Кафедра технологии органических веществ и полимерных материалов (ТОВПМ)
Andere auteurs: Saranchina N. V. Nadezhda Vasilievna, Gavrilenko M. A. Mikhail Alekseevich
Samenvatting:Title screen
A colorimetric sensor is proposed for the determination of cobalt. It is prepared by immobilizing 1-(2-pyridylazo)-2-naphthol (PAN) in an optically transparent polymethacrylate matrix. The conditions for determining cobalt by the proposed colorimetric sensor are found in the study of the complexation of cobalt with a PAN-modified polymethacrylate matrix. The determination is based on the interaction of the sensor with a cobalt solution at pH 4 for 5 min, followed by the measurement of absorbance at 620 nm. The sensor ensures the determination of 0.05–0.50 mg/L of cobalt with the detection limit 0.03 mg/L. It is demonstrated that the sensor can be used for the determination of cobalt in the Cyanocobalamin medical preparation and potable water.
Режим доступа: по договору с организацией-держателем ресурса
Taal:Engels
Gepubliceerd in: 2015
Onderwerpen:
Online toegang:http://dx.doi.org/10.1134/S1061934815120060
Formaat: Elektronisch Hoofdstuk
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=645148
Omschrijving
Samenvatting:Title screen
A colorimetric sensor is proposed for the determination of cobalt. It is prepared by immobilizing 1-(2-pyridylazo)-2-naphthol (PAN) in an optically transparent polymethacrylate matrix. The conditions for determining cobalt by the proposed colorimetric sensor are found in the study of the complexation of cobalt with a PAN-modified polymethacrylate matrix. The determination is based on the interaction of the sensor with a cobalt solution at pH 4 for 5 min, followed by the measurement of absorbance at 620 nm. The sensor ensures the determination of 0.05–0.50 mg/L of cobalt with the detection limit 0.03 mg/L. It is demonstrated that the sensor can be used for the determination of cobalt in the Cyanocobalamin medical preparation and potable water.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.1134/S1061934815120060