Development of a High-Frequency Emissive Probe System for Plasma Potential Measurements in a Hall Thruster; IEEE Transactions on Plasma Science; Vol. 43, iss. 1
| Parent link: | IEEE Transactions on Plasma Science.— , 1973- Vol. 43, iss. 1.— 2015.— [P. 29-34] |
|---|---|
| Ente Autore: | |
| Altri autori: | , , , |
| Riassunto: | Title screen A heated emissive probe is a smart diagnostic tool for acquisition of the plasma potential in the discharge and in the plume of a Hall thruster. However, measurements of high-frequency oscillations of the potential require a specific electrical circuit with a low RC time constant. We developed and tested an emissive probe system with a cutoff frequency of 1 MHz. Details about the low-pass filter design as well as first experimental outcomes obtained in the plume of a 200 W permanent magnet Hall thruster are given in this paper. Режим доступа: по договору с организацией-держателем ресурса |
| Lingua: | inglese |
| Pubblicazione: |
2015
|
| Soggetti: | |
| Accesso online: | http://dx.doi.org/10.1109/TPS.2014.2316322 |
| Natura: | Elettronico Capitolo di libro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=644922 |
MARC
| LEADER | 00000nla0a2200000 4500 | ||
|---|---|---|---|
| 001 | 644922 | ||
| 005 | 20260715071708.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\10006 | ||
| 035 | |a RU\TPU\network\9720 | ||
| 090 | |a 644922 | ||
| 100 | |a 20151204d2015 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Development of a High-Frequency Emissive Probe System for Plasma Potential Measurements in a Hall Thruster |f S. Mazouffre [et al.] | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: p. 34 (26 tit.)] | ||
| 330 | |a A heated emissive probe is a smart diagnostic tool for acquisition of the plasma potential in the discharge and in the plume of a Hall thruster. However, measurements of high-frequency oscillations of the potential require a specific electrical circuit with a low RC time constant. We developed and tested an emissive probe system with a cutoff frequency of 1 MHz. Details about the low-pass filter design as well as first experimental outcomes obtained in the plume of a 200 W permanent magnet Hall thruster are given in this paper. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t IEEE Transactions on Plasma Science |d 1973- | ||
| 463 | |t Vol. 43, iss. 1 |v [P. 29-34] |d 2015 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 701 | 1 | |a Mazouffre |b S. | |
| 701 | 1 | |a Petin |b A. | |
| 701 | 1 | |a Kudrna |b P. | |
| 701 | 1 | |a Tichy |b M. |c chemist |c Professor of Tomsk Polytechnic University, Doctor of physical and mathematical sciences |f 1947- |g Milan |3 (RuTPU)RU\TPU\pers\35771 | |
| 712 | 0 | 2 | |a Томский политехнический университет |c 1991- |7 ca |8 rus |9 26305 |
| 801 | 2 | |a RU |b 63413507 |c 20170118 |g RCR | |
| 850 | |a 63413507 | ||
| 856 | 4 | |u http://dx.doi.org/10.1109/TPS.2014.2316322 | |
| 942 | |c CF | ||