Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron; Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms; Vol. 267, iss. 5

Bibliografiske detaljer
Parent link:Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms: Scientific Journal.— , 1984-
Vol. 267, iss. 5.— 2009.— [P. 777-780]
Andre forfattere: Kaplin V. V. Valery Viktorovich, Uglov S. R. Sergey Romanovich, Sohoreva V.V., Bulaev O. F., Voronin A. A., Piestrup M., Gary C., Fuller M.
Summary:Title screen
The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer.
Режим доступа: по договору с организацией-держателем ресурса
Sprog:engelsk
Udgivet: 2009
Fag:
Online adgang:http://dx.doi.org/10.1016/j.nimb.2008.11.014
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=644896

MARC

LEADER 00000nla0a2200000 4500
001 644896
005 20250318154226.0
035 |a (RuTPU)RU\TPU\network\9980 
035 |a RU\TPU\network\9931 
090 |a 644896 
100 |a 20151203d2009 k||y0rusy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Parametric X-rays generated by electrons in multilayer mirrors mounted inside a betatron  |f V. V. Kaplin [еt al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 780 (3 tit.)] 
330 |a The measured characteristics of tunable, quasi-monochromatic X-rays from thin multilayer mirrors used as radiators mounted inside a 35 MeV betatron chamber are presented. Parametric X-ray radiation (PXR) was generated by 15-33 MeV electrons passing through two radiators consisted of a few hundreds of W/B4C bilayers with period of 14.86 and 18 A. Shifts of the PXR spectra were measured as the orientation of the multilayer radiators relative to the incident electron beam was changed. The PXR flux was determined by comparison with the yield of L fluorescence generated by electrons in the W layers of the multilayer. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms  |o Scientific Journal  |d 1984- 
463 |t Vol. 267, iss. 5  |v [P. 777-780]  |d 2009 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a prametric X-rays 
610 1 |a periodic nanostructure 
610 1 |a X-ray mirror 
701 1 |a Kaplin  |b V. V.  |c physicist  |c senior research fellow at Tomsk Polytechnic University  |f 1947-  |g Valery Viktorovich  |3 (RuTPU)RU\TPU\pers\31532  |9 15693 
701 1 |a Uglov  |b S. R.  |c physicist  |c Leading Researcher of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1958-  |g Sergey Romanovich  |3 (RuTPU)RU\TPU\pers\31533  |9 15694 
701 1 |a Sohoreva  |b V.V. 
701 1 |a Bulaev  |b O. F. 
701 1 |a Voronin  |b A. A. 
701 1 |a Piestrup  |b M. 
701 1 |a Gary  |b C. 
701 1 |a Fuller  |b M. 
801 2 |a RU  |b 63413507  |c 20151204  |g RCR 
856 4 |u http://dx.doi.org/10.1016/j.nimb.2008.11.014 
942 |c CF