Development of High Resolution Shearography Device for Non-destructive Testing of Composite Materials

Մատենագիտական մանրամասներ
Parent link:AIP Conference Proceedings
Vol. 1683 : Advanced Materials with Hierarchical Structure for New Technologies and Reliable Structures.— 2015.— [020029, 5 p.]
Համատեղ հեղինակ: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра материаловедения в машиностроении (ММС)
Այլ հեղինակներ: Burkov M. V. Mikhail Vladimirovich, Lyubutin P. S. Pavel Stepanovich, Byakov A. V. Anton Viktorovich, Panin S. V. Sergey Viktorovich
Ամփոփում:Title screen
The paper presents the results of preliminary testing of high-resolution shearographic device and software for signal processing to be applied for non-destructive evaluation (NDE) of composite materials. Shearography is an interferometric non-contact NDT/E method that allows obtaining strain data straightly at video frame rate to diagnose different composite structures to provide the safe operation of the structure and reduce the possibility of accidents. The optical part of the device based on the Canon 450D DSLR camera is described. The tests have been performed to ensure the proper functioning of the device and to establish the image processing technique.
Режим доступа: по договору с организацией-держателем ресурса
Հրապարակվել է: 2015
Խորագրեր:
Առցանց հասանելիություն:http://dx.doi.org/10.1063/1.4932719
Ձևաչափ: Էլեկտրոնային Գրքի գլուխ
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=644871
Նկարագրություն
Ամփոփում:Title screen
The paper presents the results of preliminary testing of high-resolution shearographic device and software for signal processing to be applied for non-destructive evaluation (NDE) of composite materials. Shearography is an interferometric non-contact NDT/E method that allows obtaining strain data straightly at video frame rate to diagnose different composite structures to provide the safe operation of the structure and reduce the possibility of accidents. The optical part of the device based on the Canon 450D DSLR camera is described. The tests have been performed to ensure the proper functioning of the device and to establish the image processing technique.
Режим доступа: по договору с организацией-держателем ресурса