Riassunto:Title screen
In this article the importance of timely diagnostics of the coagulation process is shown and the opportunity to use for this purpose the previously described method of photometry study of droplet samples is presented. The initial methodology of carrying out experiments and the analysis of a shape of the obtained photometric curves are given. It is defined that the most informative are the optical curves obtained at the receiver location in the optical focus, formed after the coagulation process. Researches on improvement of the methodology of carrying out experiments in order to improve the sensitivity and repeatability of our method are presented. On the basis of the experiments the order of reagents introduction on photometric cuvette was determined. A comparative analysis of the dynamics of the photometric curves, depending on the method of reagents mixing is carried out.
Режим доступа: по договору с организацией-держателем ресурса
Lingua:inglese
Pubblicazione: 2015
Soggetti:
Accesso online:http://dx.doi.org/10.1109/SIBCON.2015.7147309
Natura: Elettronico Capitolo di libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=644445

MARC

LEADER 00000naa0a2200000 4500
001 644445
005 20250606192415.0
035 |a (RuTPU)RU\TPU\network\9526 
090 |a 644445 
100 |a 20151117d2015 k||y0engy50 ba 
101 0 |a eng 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Development of the micromethod of evaluation of the coagulation process  |f E. V. Nosova, A. A. Aristov 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: 3 tit.] 
330 |a In this article the importance of timely diagnostics of the coagulation process is shown and the opportunity to use for this purpose the previously described method of photometry study of droplet samples is presented. The initial methodology of carrying out experiments and the analysis of a shape of the obtained photometric curves are given. It is defined that the most informative are the optical curves obtained at the receiver location in the optical focus, formed after the coagulation process. Researches on improvement of the methodology of carrying out experiments in order to improve the sensitivity and repeatability of our method are presented. On the basis of the experiments the order of reagents introduction on photometric cuvette was determined. A comparative analysis of the dynamics of the photometric curves, depending on the method of reagents mixing is carried out. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
463 |t Control and Communications (SIBCON)  |o International Siberian Conference on Russia, Omsk, May 21-23, 2015  |v [4 p.]  |o [proceedings]  |d 2015 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a плазма 
610 1 |a плазма крови 
610 1 |a свертывание 
610 1 |a фиброгенез 
610 1 |a сгустки 
700 1 |a Nosova  |b E. V.  |c specialist in the field of electronics  |c engineer of Tomsk Polytechnic University  |f 1988-  |g Ekaterina Vladimirovna  |3 (RuTPU)RU\TPU\pers\34736 
701 1 |a Aristov  |b A. A.  |c specialist in the field of electronics  |c Associate Professor of Tomsk Polytechnic University, Candidate of technical sciences  |f 1972-  |g Aleksandr Aleksandrovich  |3 (RuTPU)RU\TPU\pers\31701  |9 15832 