A probe for diagnosing charged particle beams; Instruments and Experimental Techniques; Vol. 58, iss. 3
| Parent link: | Instruments and Experimental Techniques.— , 1956- Vol. 58, iss. 3.— 2015.— [P. 395-398] |
|---|---|
| Autore principale: | |
| Ente Autore: | |
| Riassunto: | Title screen Probes for diagnosing charged particle beams have been developed. An extended probe in the form of a single carbon fiber is tested on the beam of a small-sized betatron. A local spherical probe on a suspension made from a single carbon fiber is proposed. The range of possible local probe dimensions under conditions of acceleration chamber vibration is experimentally determined. The operating range of current densities for accelerated electrons of the sounded beam is evaluated by results of the thermal stability tests for copper probe under high vacuum. Режим доступа: по договору с организацией-держателем ресурса |
| Lingua: | inglese |
| Pubblicazione: |
2015
|
| Soggetti: | |
| Accesso online: | http://dx.doi.org/10.1134/S0020441215020256 |
| Natura: | Elettronico Capitolo di libro |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=642007 |
MARC
| LEADER | 00000naa0a2200000 4500 | ||
|---|---|---|---|
| 001 | 642007 | ||
| 005 | 20250408093700.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\6938 | ||
| 035 | |a RU\TPU\network\1863 | ||
| 090 | |a 642007 | ||
| 100 | |a 20150611d2015 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a A probe for diagnosing charged particle beams |f V. B. Sorokin | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: 1 tit.] | ||
| 330 | |a Probes for diagnosing charged particle beams have been developed. An extended probe in the form of a single carbon fiber is tested on the beam of a small-sized betatron. A local spherical probe on a suspension made from a single carbon fiber is proposed. The range of possible local probe dimensions under conditions of acceleration chamber vibration is experimentally determined. The operating range of current densities for accelerated electrons of the sounded beam is evaluated by results of the thermal stability tests for copper probe under high vacuum. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Instruments and Experimental Techniques |d 1956- | ||
| 463 | |t Vol. 58, iss. 3 |v [P. 395-398] |d 2015 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 700 | 1 | |a Sorokin |b V. B. |c Physicist |c Senior researcher of Tomsk Polytechnic University |f 1946- |g Vladimir Borisovich |3 (RuTPU)RU\TPU\pers\34819 |9 18165 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Институт неразрушающего контроля (ИНК) |b Лаборатория № 42 (Сильноточных бетатронов) |3 (RuTPU)RU\TPU\col\19919 |
| 801 | 2 | |a RU |b 63413507 |c 20180305 |g RCR | |
| 856 | 4 | |u http://dx.doi.org/10.1134/S0020441215020256 | |
| 942 | |c CF | ||