Thermal Efficiency of Three-Cycle Utilization-Type Steam-Gas Units; Power Technology and Engineering; Vol. 48, iss. 6

Bibliographische Detailangaben
Parent link:Power Technology and Engineering: Scientific Journal
Vol. 48, iss. 6.— 2015.— [P. 459-463]
1. Verfasser: Galashov N. N. Nikolay Nikitovich
Körperschaft: Национальный исследовательский Томский политехнический университет (ТПУ) Энергетический институт (ЭНИН) Кафедра атомных и тепловых электростанций (АТЭС)
Weitere Verfasser: Tsibulskii (Tsibulskiy) S. A. Svyatoslav Anatolievich
Zusammenfassung:Title screen
This is a study of the efficiency of combined-cycle plants (steam-gas units) operating in three cycles– a Brayton gas-turbine cycle and two Rankine steam-turbine cycles, one of which runs on water vapor and the other on the vapor of a low-boiling substance. An analytic expression is obtained for the dependence of the internal efficiency of a three-cycle combined cycle plant on the internal efficiencies of the individual cycles and the efficiency of the boiler-utilizer. Coefficients representing the influence of the efficiencies for each cycle and for the boiler-utilizer on the efficiency of a combined-cycle plant are obtained by regression analysis.
Режим доступа: по договору с организацией-держателем ресурса
Sprache:Englisch
Veröffentlicht: 2015
Schlagworte:
Online-Zugang:http://dx.doi.org/10.1007/s10749-015-0555-9
Format: Elektronisch Buchkapitel
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=640553