Possibility of Using {99m}Tc-HMPAO in Estimating Long-Term Prognosis of Cerebral Complications of Coronary Artery Bypass Graft; Advanced Materials Research : Radiation and nuclear techniques in material science; Vol. 1084 : Physical-Technical Problems of Nuclear Science, Energy Generation, and Power Industry (PTPAI -2014)

Podrobná bibliografie
Parent link:Advanced Materials Research : Radiation and nuclear techniques in material science: Scientific Journal
Vol. 1084 : Physical-Technical Problems of Nuclear Science, Energy Generation, and Power Industry (PTPAI -2014).— 2015.— [P. 438-442]
Korporativní autor: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Лаборатория № 31 ядерного реактора (Лаборатория № 31 ЯР)
Další autoři: Lishmanov Yu. B. Yury Borisovich, Efimova N. Yu. Nataliya Yurievna, Chernov V. I. Vladimir Ivanovich, Efimova I. Y., Akhmedov S. D.
Shrnutí:Title screen
The aim of this work was to investigate the possibility of using brain SPECT with {99m}Tc-HMPAO to estimate long-term prognosis of the development of neurocognitive deficits in patients after coronary artery bypass graft (CABG). The study included 22 patients with coronary artery disease who underwent a standard estimate of neurological status, 99mTc-HMPAO brain SPECT and neuropsychological testing before CABG, 14 days and 6 months after surgical intervention. The results showed that {99m}Tc-HMPAO is useful radiopharmaceutical for evaluation of long-term prognosis of the development of neurocognitive deficits in patients after CABG. Thus, in 96% of patients after CABG one could observe the early cognitive deficit, which persisted in 55% of cases after 6 months. At that, a correlation between the deterioration of long-term memory after 6 months and a decrease in perfusion in the temporal lobes was detected in the early postoperative period.
Режим доступа: по договору с организацией-держателем ресурса
Jazyk:angličtina
Vydáno: 2015
Edice:Radiation Technologies in Medicine
Témata:
On-line přístup:http://dx.doi.org/10.4028/www.scientific.net/AMR.1084.438
Médium: Elektronický zdroj Kapitola
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=640405

MARC

LEADER 00000nla2a2200000 4500
001 640405
005 20231101134119.0
035 |a (RuTPU)RU\TPU\network\4952 
035 |a RU\TPU\network\4945 
090 |a 640405 
100 |a 20150416a2015 k y0engy50 ba 
101 0 |a eng 
105 |a y z 100zy 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Possibility of Using {99m}Tc-HMPAO in Estimating Long-Term Prognosis of Cerebral Complications of Coronary Artery Bypass Graft  |f Yu. B. Lishmanov [et al.] 
203 |a Text  |c electronic 
225 1 |a Radiation Technologies in Medicine 
300 |a Title screen 
330 |a The aim of this work was to investigate the possibility of using brain SPECT with {99m}Tc-HMPAO to estimate long-term prognosis of the development of neurocognitive deficits in patients after coronary artery bypass graft (CABG). The study included 22 patients with coronary artery disease who underwent a standard estimate of neurological status, 99mTc-HMPAO brain SPECT and neuropsychological testing before CABG, 14 days and 6 months after surgical intervention. The results showed that {99m}Tc-HMPAO is useful radiopharmaceutical for evaluation of long-term prognosis of the development of neurocognitive deficits in patients after CABG. Thus, in 96% of patients after CABG one could observe the early cognitive deficit, which persisted in 55% of cases after 6 months. At that, a correlation between the deterioration of long-term memory after 6 months and a decrease in perfusion in the temporal lobes was detected in the early postoperative period. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 1 |0 (RuTPU)RU\TPU\network\4598  |t Advanced Materials Research : Radiation and nuclear techniques in material science  |o Scientific Journal 
463 1 |0 (RuTPU)RU\TPU\network\4600  |t Vol. 1084 : Physical-Technical Problems of Nuclear Science, Energy Generation, and Power Industry (PTPAI -2014)  |o The VIth International Conference, June 5-7, 2014, Tomsk, Russia  |o [proceedings]  |f National Research Tomsk Polytechnic University (TPU)  |v [P. 438-442]  |d 2015 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a головной мозг 
610 1 |a шунтирование 
610 1 |a кровообращение 
610 1 |a эмиссионная томография 
610 1 |a компьютерная томография 
701 1 |a Lishmanov  |b Yu. B.  |c specialist in the field of medical technology  |c lead engineer aof Tomsk Polytechnic University, doctor of medical sciences  |f 1951-  |g Yury Borisovich  |2 stltpush  |3 (RuTPU)RU\TPU\pers\34200 
701 1 |a Efimova  |b N. Yu.  |c specialist in the field of medical technology  |c laboratory assistant of Tomsk Polytechnic University, Doctor of medical science  |f 1972-  |g Nataliya Yurievna  |2 stltpush  |3 (RuTPU)RU\TPU\pers\34257 
701 1 |a Chernov  |b V. I.  |c specialist in the field of medical technology  |c lead engineer of Tomsk Polytechnic University, doctor of medical sciences  |f 1962-  |g Vladimir Ivanovich  |2 stltpush  |3 (RuTPU)RU\TPU\pers\34191 
701 1 |a Efimova  |b I. Y. 
701 1 |a Akhmedov  |b S. D. 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Физико-технический институт (ФТИ)  |b Лаборатория № 31 ядерного реактора (Лаборатория № 31 ЯР)  |h 6471  |2 stltpush  |3 (RuTPU)RU\TPU\col\20054 
801 2 |a RU  |b 63413507  |c 20161228  |g RCR 
856 4 |u http://dx.doi.org/10.4028/www.scientific.net/AMR.1084.438 
942 |c CF