High Power Microwave Compressor with Two Output Units for Synchronous Energy Extraction

Bibliographic Details
Parent link:Advanced Materials Research : Radiation and nuclear techniques in material science: Scientific Journal.— , 1994-
Vol. 1084 : Physical-Technical Problems of Nuclear Science, Energy Generation, and Power Industry (PTPAI -2014).— 2015.— [P. 262-265]
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Лаборатория № 46
Other Authors: Avgustinovich V. A. Vladimir Andreevich, Artemenko S. N. Sergey Nikolaevich, Gorev S. A. Stanislav Andreevich, Igumnov V. S. Vladislav Sergeevich, Kaminsky V. L. Valery Ludvigovich, Novikov S. A. Sergey Avtonomovich, Yushkov Y. G. Yuri Georgievich
Summary:Title screen
The compressor contains the oversized cylindrical cavity with two interference output units each in the figure of a circular waveguide H-tee. The H-tees are coupled by a waveguide section and the energy is extracted synchronously through two output ports. The synchronism is provided through using a single microwave switch mutual for both H-tees. Simulation and experimental study of the X-band microwave compressor were carried out. The simulation made it possible to optimize the configuration of the oversized storage cavity and the output element. The amplification factor was 14 dB when the energy was extracted though one output unit at the output pulsewidth of 6...7 ns. Amplification factor and the output power were increased by 2dB and the pulsewidth was decreased down to 3...3.5 ns when the energy was extracted synchronously through two output units.
Режим доступа: по договору с организацией-держателем ресурса
Published: 2015
Series:Plasma, Microwave, Ion, Electron and Isotope Technologies
Subjects:
Online Access:http://dx.doi.org/10.4028/www.scientific.net/AMR.1084.262
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=640308
Description
Summary:Title screen
The compressor contains the oversized cylindrical cavity with two interference output units each in the figure of a circular waveguide H-tee. The H-tees are coupled by a waveguide section and the energy is extracted synchronously through two output ports. The synchronism is provided through using a single microwave switch mutual for both H-tees. Simulation and experimental study of the X-band microwave compressor were carried out. The simulation made it possible to optimize the configuration of the oversized storage cavity and the output element. The amplification factor was 14 dB when the energy was extracted though one output unit at the output pulsewidth of 6...7 ns. Amplification factor and the output power were increased by 2dB and the pulsewidth was decreased down to 3...3.5 ns when the energy was extracted synchronously through two output units.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.4028/www.scientific.net/AMR.1084.262