The dosymetric parameters investigation of the pulsed gamma radiation source based on betatron

Detalles Bibliográficos
Parent link:12th International Conference on Actual Problems of Electronic Instrument Engineering (APEIE), October 2-4 , 2014, Novosibirsk. [P. 252-254].— , 2014
Autor Corporativo: Национальный исследовательский Томский политехнический университет (ТПУ) Институт физики высоких технологий (ИФВТ) Кафедра общей химии и химической технологии (ОХХТ)
Outros autores: Miloichikova I. A. Irina Alekseevna, Stuchebrov S. G. Sergey Gennadevich, Wagner A. R. Aleksandr Rudolfovich, Zhaksybaeva G. K. Gulnur Kapizkyzy
Summary:Title screen
In the paper the dosimetric parameters measurement technique of the pulsed bremsstrahlung generated by betatron is described. The dose and the dose rate measurement results from the pulsed bremsstrahlung generated by betatron are presented. The dose rate spatial distributions of the pulsed bremsstrahlung generated by betatron obtained with the help of the thermoluminescent dosimeters DTL-02 and the cylindrical ionization chamber type 30013 are demonstrated.
Idioma:inglés
Publicado: 2014
Subjects:
Acceso en liña:http://dx.doi.org/10.1109/APEIE.2014.7040890
Formato: Electrónico Capítulo de libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=640064

MARC

LEADER 00000naa0a2200000 4500
001 640064
005 20250228125702.0
035 |a (RuTPU)RU\TPU\network\4594 
090 |a 640064 
100 |a 20150408d2014 k||y0rusy50 ba 
101 0 |a eng 
102 |a RU 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a The dosymetric parameters investigation of the pulsed gamma radiation source based on betatron  |f I. A. Miloichikova [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 254 (4 tit.)] 
330 |a In the paper the dosimetric parameters measurement technique of the pulsed bremsstrahlung generated by betatron is described. The dose and the dose rate measurement results from the pulsed bremsstrahlung generated by betatron are presented. The dose rate spatial distributions of the pulsed bremsstrahlung generated by betatron obtained with the help of the thermoluminescent dosimeters DTL-02 and the cylindrical ionization chamber type 30013 are demonstrated. 
463 |t 12th International Conference on Actual Problems of Electronic Instrument Engineering (APEIE), October 2-4 , 2014, Novosibirsk  |v [P. 252-254]  |d 2014 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Miloichikova  |b I. A.  |c physicist  |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1988-  |g Irina Alekseevna  |3 (RuTPU)RU\TPU\pers\35525  |9 18707 
701 1 |a Stuchebrov  |b S. G.  |c physicist  |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences  |f 1981-  |g Sergey Gennadevich  |3 (RuTPU)RU\TPU\pers\31559  |9 15719 
701 1 |a Wagner  |b A. R.  |c physicist  |c associate professor of Tomsk Polytechnic Unive  |f 1983-  |g Aleksandr Rudolfovich  |3 (RuTPU)RU\TPU\pers\31560 
701 1 |a Zhaksybaeva  |b G. K.  |g Gulnur Kapizkyzy 
712 0 2 |a Национальный исследовательский Томский политехнический университет (ТПУ)  |b Институт физики высоких технологий (ИФВТ)  |b Кафедра общей химии и химической технологии (ОХХТ)  |3 (RuTPU)RU\TPU\col\21253 
801 2 |a RU  |b 63413507  |c 20190628  |g RCR 
856 4 |u http://dx.doi.org/10.1109/APEIE.2014.7040890 
942 |c CF