Determining direct measures of performance based on the location of zeros and pole of the transfer function; Optoelectronics, Instrumentation and Data Processing; Vol. 47, iss. 3

מידע ביבליוגרפי
Parent link:Optoelectronics, Instrumentation and Data Processing
Vol. 47, iss. 3.— 2011.— [P. 297-302]
מחבר ראשי: Efimov S. V. Semyon Viktorovich
מחבר תאגידי: Национальный исследовательский Томский политехнический университет (ТПУ) Институт кибернетики (ИК) Кафедра автоматики и компьютерных систем (АИКС)
מחברים אחרים: Pushkarev M. I. Maksim Ivanovich
סיכום:Title screen
An analysis is made of the effect of zeros and poles of a closed-loop automatic control system on its direct measures of performance: overcontrol and control time. The necessity of determining the dominant poles in the root-locus plane is shown. A criterion for the ?-dominance of the components of the transient function of automatic control system is presented. A method for calculating direct measures of performance based on the location of zeros and poles of the system is developed. Numerical examples are considered.