Determining direct measures of performance based on the location of zeros and pole of the transfer function

Bibliographic Details
Parent link:Optoelectronics, Instrumentation and Data Processing
Vol. 47, iss. 3.— 2011.— [P. 297-302]
Main Author: Efimov S. V. Semyon Viktorovich
Corporate Author: Национальный исследовательский Томский политехнический университет (ТПУ) Институт кибернетики (ИК) Кафедра автоматики и компьютерных систем (АИКС)
Other Authors: Pushkarev M. I. Maksim Ivanovich
Summary:Title screen
An analysis is made of the effect of zeros and poles of a closed-loop automatic control system on its direct measures of performance: overcontrol and control time. The necessity of determining the dominant poles in the root-locus plane is shown. A criterion for the ?-dominance of the components of the transient function of automatic control system is presented. A method for calculating direct measures of performance based on the location of zeros and poles of the system is developed. Numerical examples are considered.
Режим доступа: по договору с организацией-держателем ресурса
Language:English
Published: 2011
Subjects:
Online Access:http://dx.doi.org/10.3103/S8756699011030137
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=639416
Description
Summary:Title screen
An analysis is made of the effect of zeros and poles of a closed-loop automatic control system on its direct measures of performance: overcontrol and control time. The necessity of determining the dominant poles in the root-locus plane is shown. A criterion for the ?-dominance of the components of the transient function of automatic control system is presented. A method for calculating direct measures of performance based on the location of zeros and poles of the system is developed. Numerical examples are considered.
Режим доступа: по договору с организацией-держателем ресурса
DOI:10.3103/S8756699011030137