The voltammetric determination of peroxynitrite at a mercury film electrode

Bibliografiske detaljer
Parent link:New Journal of Chemistry
Vol. 31, iss. 3.— 2007.— [P. 394-400]
Andre forfattere: Zakharova E. A. Elsa Arminana, Yurmazova T. A. Tatyana Aleksandrovna, Nazaarov B. F., Wildgoose G. G., Compton R. G.
Summary:Title screen
This report describes the direct voltammetric detection of peroxynitrite (PN, ONOO-), an important analyte in many physiological biochemical pathways, at a mercury film electrode (MFE) at alkaline pH. The voltammetric response of PN is observed as a cathodic inverted peak when the potential is swept in the oxidative direction at ca. -0.1 V vs. a Ag/AgCl/1 M KCl reference electrode. An Image ID:b615188d-t2.gif mechanism is proposed to explain this behaviour involving the initial formation of a thin film of Hg(I) oxide on the electrode which is then oxidised by PN to form HgO in a chemical step. The HgO is then reduced back to Hg(0) at the electrode potential of interest resulting in a net cathodic current. The parameters affecting the voltammetry of PN at a MFE, including the concentration of PN (10-5–10-4 M), the effect of varying scan rate (5–100 mV s-1) and pH are investigated and the kinetics of PN decay in alkaline solutions ranging from pH 9–13 are explored electrochemically.
Режим доступа: по договору с организацией-держателем ресурса
Sprog:engelsk
Udgivet: 2007
Fag:
Online adgang:http://pubs.rsc.org/en/Content/ArticleLanding/2007/NJ/b615188d#!divAbstract
Format: Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=638348

MARC

LEADER 00000naa0a2200000 4500
001 638348
005 20250131112349.0
035 |a (RuTPU)RU\TPU\network\2657 
090 |a 638348 
100 |a 20150114d2007 k||y0rusy50 ba 
101 0 |a eng 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a The voltammetric determination of peroxynitrite at a mercury film electrode  |f E. A. Zakharova [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [References: p. 400 (33 tit.)] 
330 |a This report describes the direct voltammetric detection of peroxynitrite (PN, ONOO-), an important analyte in many physiological biochemical pathways, at a mercury film electrode (MFE) at alkaline pH. The voltammetric response of PN is observed as a cathodic inverted peak when the potential is swept in the oxidative direction at ca. -0.1 V vs. a Ag/AgCl/1 M KCl reference electrode. An Image ID:b615188d-t2.gif mechanism is proposed to explain this behaviour involving the initial formation of a thin film of Hg(I) oxide on the electrode which is then oxidised by PN to form HgO in a chemical step. The HgO is then reduced back to Hg(0) at the electrode potential of interest resulting in a net cathodic current. The parameters affecting the voltammetry of PN at a MFE, including the concentration of PN (10-5–10-4 M), the effect of varying scan rate (5–100 mV s-1) and pH are investigated and the kinetics of PN decay in alkaline solutions ranging from pH 9–13 are explored electrochemically. 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
461 |t New Journal of Chemistry 
463 |t Vol. 31, iss. 3  |v [P. 394-400]  |d 2007 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
701 1 |a Zakharova  |b E. A.  |c chemist  |c senior research fellow at the Tomsk Polytechnic University, candidate of chemical Sciences  |f 1938-  |g Elsa Arminana  |3 (RuTPU)RU\TPU\pers\33332 
701 1 |a Yurmazova  |b T. A.  |c chemist  |c associate Professor of Tomsk Polytechnic University, candidate of chemical Sciences  |f 1950-  |g Tatyana Aleksandrovna  |3 (RuTPU)RU\TPU\pers\33294 
701 1 |a Nazaarov  |b B. F. 
701 1 |a Wildgoose  |b G. G. 
701 1 |a Compton  |b R. G. 
801 2 |a RU  |b 63413507  |c 20150123  |g RCR 
856 4 |u http://pubs.rsc.org/en/Content/ArticleLanding/2007/NJ/b615188d#!divAbstract 